跳至主要内容
临床试验/NCT05134311
NCT05134311尚未招募不适用

Examining the Use of Three Dimensional Ultrasound in the Assessment of Vascular Pathologies

Northwell Health0 个研究点目标入组 270 人开始时间: 2025年2月1日最近更新:
适应症

试验速览

阶段
不适用
状态
尚未招募
入组人数
270
主要终点
30 Day re-admission

研究概览

简要总结

The ability to have a visual aid to depict areas of vascular disease that are affecting the patient's health can help in patient comprehension of the problem. This comprehension can lead to better understanding of the issue and increase patient compliance to treatment. The hand drawn sketch produced by the ultrasound technologist provides an inadequate visualization of the vascular insufficiency that is causing the patient's symptoms.

PIUR imaging has developed PIUR Infinity tUS, a 3D freehand tomographic ultrasound system capable of rapid, safe and accurate reconstructive 3D quantifiable vascular imaging. This system will provide a low cost and reproducible imaging solution that will be an effective educational tool for people with vascular disease.

详细描述

Peripheral arterial disease (PAD) affects approximately 10% of the American population, with 30% to 40% of these patients presenting with claudication symptoms. The prevalence of PAD increases with age and the number of vascular risk factors. More importantly, it is a marker of atherosclerotic disease burden, and is associated with increased mortality from cardiovascular and cerebrovascular causes. There have been recent advances in noninvasive imaging, endovascular approaches for revascularization, and aggressive risk factor management for prevention of cardiac and cerebrovascular complications in PAD.

Ultrasound scanning imaging systems are currently the primary choice for vascular diagnostics. After a standard vascular study, the ultrasound technologist produces a handwritten sketch that highlights various parameters (vessel size and blood flow) throughout the vasculature in question. This sketch is then interpreted by the physician who then assesses and, if need be, performs interventions. This sketch is shown to the patient to better illustrate the vascular insufficiency issues that are affecting the patient. A digital copy of the sketch is also uploaded to the patient portal.

Due to a limited field of action and poor quantification accuracy, patients are often referred for secondary scanning procedures such as computed tomography angiography, magnetic resonance angiography and catheter angiography for more detailed imaging. Referrals delay treatment, expose the patient to potential health risks and pose higher costs to healthcare providers. This can lead to poor patient compliance and avoidable hospital readmissions. This presents a need to improve the rapidity and safety of the diagnosis of vascular conditions in patients to enable rapid treatment of conditions such as peripheral artery disease. There is also a need for cost effective preventative screening and surveillance to enable early intervention, for example, people at high risk of limb amputation.

The PIUR tUS Imaging System has been approved for use in the European Union for over 1 year. Studies performed in Europe have highlighted the system's ability to accurately depict various pathologies in a 3D form. Currently, there is no market equivalent of this technology approved by the FDA for use in the United States. We are conducting this study to determine whether the 3D images created by the device shown to patients can be used as an educational tool to increase patient comprehension of the disease process, compared with the standard of care 2D images. This will be measured in terms of compliance with follow-up appointments and 30-day readmission rates.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age 18 years of age or older
  • Suspected vascular insufficiency that requires ultrasound evaluation
  • Subject is able to sign a consent form
  • Scheduled ultrasound testing at the wound center to evaluate vasculature

排除标准

  • Younger than 18 years old
  • Subject is not scheduled to have ultrasound testing at the wound center
  • Subject is unable to or refuses to consent to participate

结局指标

主要结局

30 Day re-admission

时间窗: 30 Days after imaging

The primary endpoint of the study will be the treatment outcomes for the patients. We will review readmission rates (30 days from the day of the ultrasound) as well as compliance to first follow-up appointment after the ultrasound of interventional cohort. These endpoints will be compared to those of a historical cohort of persons who were treated for similar pathologies in the past.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor