MedPath

The Influence of Head and Neck Position About Oropharyngeal Leak Pressure and Sealing Between the Laryngeal Mask and Vocal Cord Using Different Types of Supraglottic Airway Device

Phase 1
Completed
Conditions
the Influence of Oropharyngeal Leak Pressure and Sealing Between the Mask and Vocal Cord During Changing Patient's Head and Neck Position
Interventions
Device: igel LMA
Device: LMA proseal
Device: air Q LMA
Device: ambu LMA
Registration Number
NCT01960673
Lead Sponsor
National Taiwan University Hospital
Brief Summary

Generally, the laryngeal mask airway is not considered in the surgery which should be changing position in the perioperative period. The shape of the pharynx changes during the head and neck movement and there is probably also a change in the force transmitted to the cuff along the airway tube. Besides, there is evidence that supraglottic airway device can be displaced with rotation. In this article, the investigators want to discuss about that oropharyngeal leak pressure and sealing between the mask and vocal cord while changing head and neck position in perioperative period using different types of supraglottic airway device.

Detailed Description

The investigators select adult patients,who are 20-80yrs old and ASA physical status I or II, receiving minor surgery, ex: breast surgery or cystoscope, participated in this randomized cross-over trial. Patients were excluded if they were in the above condition. The patient is at high risk of aspiration, ex:obesity, pregnancy upper GI bleeding or not enough fasting time. The patient could not open mouth or upper airway obstruction. The patient receive major surgery, ex: heart, brain, lung, liver, kidney surgery. The patient has abnormal heart and lung function.

The patient received different types of supraglottic airway device like proseal LMA,ambu LMA, air Q LMA or igel LMA by draw, then the patients will be divided into different groups.In the preoperative period, the investigators documented oropharyngeal leak pressure in these selected positions: neutral position( 0 degree),and rotation 15, 30,45, 60 degrees, etc. However, oropharyngeal leak pressure was measured by closing the expiratory valve of the circle system at fixed O2 flow 3L/min and 20 cm H2O. If the ambu bag is flattening, the investigators will think the leakage happened between the laryngeal mask and our vocal cord. Then the investigators use fiberscope to observe the condition between the epiglottis and the laryngeal mask.

The investigators wanted to compared the mean leak pressure at different head and neck rotation position,ex:neutral,30,45,60 degrees,by using many different types of supraglottic airway device.

The observers define the relationship between epiglottis and vocal cord to describe the condition when the patient is at different degree of head and neck position. Grade I is vocal cord completely visible. Grade IIA is only partially vocal cord visible and epiglottis noted. Grade IIB is no vocal cord visible and only epiglottis noted. Grade III is other condition, ex:trapped epiglottis or no epiglottis visible.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
120
Inclusion Criteria

Not provided

Exclusion Criteria

Not provided

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
igel LMAigel LMAigel LMA did not have cuff. The shape, softness and contours accurately mirror the perilaryngeal anatomy. The investigator want to test the efficacy of the igel at 30,45,60 degree of head and neck position.
LMA prosealLMA prosealThe investigator will use proseal LMA in this study. The cuff of the proseal LMA could be inflation. It is thought to fix the larynx shape. The investigator wants to test the efficacy during 30,45,60 degree of head and neck position.
air Q LMAair Q LMAThe air-Q LMA should be used routinely as a classic passive airway. It is user-friendly, placement in patients is easy and air movement is outstanding. It has the added benefit of allowing for intubation using standard ET Tubes. It also has the cuff and the contour of the mask is thought to mimic the the shape of the perilaryngeal region. The investigator want to test the efficacy of the air Q LMA at 30,45,60 degree of the head and neck position.
ambu LMAambu LMAambu LMA is also an cuff device LMA. The investigator wanted to test the efficacy about the leak pressure and the view at 30,45,60 degree of head and neck position.
Primary Outcome Measures
NameTimeMethod
the leakage happened between the laryngeal mask and our vocal cordIf the ambu bag is flattening during the surgery, the observers check the leak pressure between the laryngeal mask and our vocal cord

The oropharyngeal leak pressure was measured by closing the expiratory valve of the circle system at fixed O2 flow 3L/min and 20 cm H2O. If the ambu bag is flattening, the observers will think the leakage happened between the laryngeal mask and the vocal cord

Secondary Outcome Measures
NameTimeMethod
Use fiberscope to observe the sealing between the mask and vocal cord while changing head and neck position in perioperative period using different types of supraglottic airway device.During the surgery

The observer uses the fiberscope to observe the sealing between the vocal cord and epiglottis.

Trial Locations

Locations (1)

Department of anesthesiology,National Taiwan University Hospital

🇨🇳

Taipei, Taiwan

© Copyright 2025. All Rights Reserved by MedPath