A Clinical Study to Compare the Accuracy and Precision of the MindTension Blink Eye Reflex Measuring (Evoked Response)Device to DANTAC Keypoint EMG System
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 38
- 试验地点
- 1
- 主要终点
- Average maximal peak levels
研究概览
简要总结
A clinical study aimed to compare the accuracy and precision of the MindTension MT1 auditory evoked response parallel to an FDA cleared device (Natus DANTEC Keypoint).
详细描述
Mindtension device measures the orbicularis muscle response to auditory stimuli, the device is backed up by an algorithm that calculates several parameters of startle reflex and startle related indices. In the present study we aim to test the validity, accuracy and precision of MT1 system compared to an FDA cleared device, the Natus DANTEC Keypoint EMG system (K944547).
The aim of this clinical trial is to demonstrate the accuracy and precision of the MT1 device to the FDA cleared Natus DANTEC Keypoint EMG system that is used in the EMG unit.
Participants (n=38) will be evaluated for eligibility of inclusion. As this is paired-group design study, patients will be randomized in a 1:1 ratio to group 1 (Right facial side with MT1 device), or group 2 (Right facial side Natus keypoint device), each patient will be tested using both devices at the same time. The test is 6 minutes in duration. The results will be compared within and between subject analysis.
Safety will be assessed through collection and analysis of adverse events.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Screening
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 45 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Subject's informed consent.
- •Healthy subjects, with no known chronic disease.
- •Both genders, age between 18-45.
排除标准
- •Any current co-morbid Chronic illness.
- •Hearing loss.
- •Pregnancy.
- •Substance abuse during the last 3 months.
- •Lack of cooperation.
结局指标
主要结局
Average maximal peak levels
时间窗: Day 1
The average peak levels (in millivolts) following auditory stimulus.
Average peak index
时间窗: Day 1
The average index (in milliseconds) following auditory stimulus.
Average eye blink width
时间窗: Day 1
Average eye blink width (in milliseconds) following auditory stimuli.
Average inhibition
时间窗: Day 1
Average inhibition (in percent) following paired auditory stimuli.
次要结局
- Average eye blink sum(Day 1)