NCT03932357Unknown不适用
Accuracy of Cone Beam Computed Tomography in Measuring of Mandibular Pig Soft Tissue Thickness Using a Radiopaque Material in Comparesion With Real Measurement.Diagnostic Study
适应症
试验速览
- 阶段
- 不适用
- 入组人数
- 15
- 试验地点
- 1
- 主要终点
- cbct
研究概览
简要总结
accuracy of CBCT in measuring soft tissue thickness by using a radiopaque material as the real finding and measurements on pig jaws
详细描述
- Pig jaws will be included in this study.
- Soft tissue surfaces were lightly covered with barium sulfate powder using a powder spray. CBCT was taken.
- A periodontal probe and a rubber stop were used for the measurement of trans-gingival probing thickness (TPT).
- After that, flap were elevated, and actual thickness of soft-tissue (actual thickness, AT) was measured.
The Analytical phase:
- In order to assess soft tissue thickness and bone levels an electronic digital caliper (Shenhan Measuring Tools Co., LTD, Shanghai) will used for measuring the transgingival probing thickness on the pig jaws.
- A graduated Naber's probe will be used for measuring the transgingival probing thickness.
Soft tissue thickness measurements:
- Intra-observer variability was tested under the supervision of the director.
- For the measurement of radiographic thickness (RT), wet soft tissue surfaces were covered with barium sulfate powder (SoloTop; Taejoon, Seoul, Korea), a radiopaque material used as a contrast medium.
- A probes and rubber stop were used for the measurement of transgingival probing thickness (TPT).
- A rubber stop was placed in contact with the surface to facilitate the measurement of tissue thickness, and then TPT was measured with digital calipers. All measurements were rounded to the nearest 0.01 mm.
- For the measurement of actual thickness (AT), an incision was made onto each marked area. After flap elevation, actual soft tissue thickness was measured using the same method that was used for TPT.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Only
- 时间视角
- Cross Sectional
入排标准
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •The study samples will not identified by age or gender group.
- •The selected pig jaw should be intact with no mechanical damage.
- •jaw with attached natural teeth
排除标准
- •Teeth with anomalies and fractures.
- •Periodontally affected teeth
结局指标
主要结局
cbct
时间窗: 6 months
measuring soft tissue thickness using cbct in pig jaw
次要结局
- Acutal thickness measurement(6 months)
研究者
Mahinaz Reda Hassan Abdelhamed
main supervisor Dr. Hoda Abd El Kader Saleh Professor, .Co-supervisor Dr: Walaa Abdelaty Associate Professor, Investigator: DR. Mahinaz Reda Hassan Assistant lecturer .
Cairo University
研究点 (1)
Loading locations...
相似试验
Unknown
不适用
Efficacy of Cone Beam Computed Tomography in Diagnosing OsteoporosisOsteoporosisNCT04365504Postgraduate Institute of Dental Sciences Rohtak48
已完成
不适用
Perfexion Registration Using CBCTBrain MetastasesNCT04170777University Health Network, Toronto1,250
已完成
不适用
Japanese National Computed Tomographic (CT) Colonography TrialColonic NeoplasmsColonic PolypsNCT00997802Japanese CT Colonography Society1,257
Unknown
不适用
Comparison of Soft and Hard Tissue Thickness in the Anterior Regions of the Upper and Lower Jaws Taken From CBCT Versus Clinical MeasurementsSoft and Hard Tissue BiotypeNCT01507961Hadassah Medical Organization100
已完成
不适用
The Efficacy of Cone Beam Computed Tomography (CBCT) Compared to Panoramic Radiography Prior to Third Molar RemovalInferior Alveolar Nerve InjuryNCT02071030Radboud University Medical Center477