MedPath

Perfexion Registration Using CBCT

Completed
Conditions
Brain Metastases
Registration Number
NCT04170777
Lead Sponsor
University Health Network, Toronto
Brief Summary

Measuring precision radiation delivery through cone-beam computed tomography (CBCT) and intra-fraction motion management (IFMM) incorporated on a GammaKnife unit via the Leksell Coordinate Frame (LCF) and relocatable mask system (RMS) immobilization devices.

Detailed Description

: Brain metastases are reported to occur in 20% to 40% of all patients with cancer. Treatment options for brain metastases include surgical resection, particularly in lesions causing significant mass effect, whole brain radiation (WBRT) and radiosurgery (SRS). Due to concerns of neurocognitive toxicity following WBRT, there is growing use of SRS, particularly in patients with limited brain metastases and controlled extracranial disease.

Radiosurgery delivers a high dose of radiation to a defined intracranial target through precise targeting with a sharp dose fall off at the target boundaries and minimal damage to surrounding tissue. To date, precision radiation delivery has been facilitated through the Leksell Coordinate Frame (LCF), fixated to the patient's skull through 4 pins. A relocatable mask system (RMS), consisting of a patient specific head rest and mask was developed to enable minimally-invasive fractioned radiosurgery.

A cone-beam computed tomography (CBCT) image guidance and intra-fraction motion management (IFMM) system was previously developed in-house in order to measure and address setup uncertainties on Gamma Knife. The in-house prototype has been integrated into a commercially available GammaKnife device with CBCT guidance. The installation of this device will enable volumetric guidance for all patients treated in either a single or multiple session on GammaKnife Perfexion.

This study is designed to have 2 arms, A and B. Both Arm A (using the Leksell Coordinate Frame) and Arm B (using the relocatable mask) are undergoing standard of care treatment on GammaKnife Perfexion for SRS. CBCT is part of standard of care for Arm B. However, CBCT imaging is considered as part of study treatment for Arm A. Pre and post treatment images will be acquired of the patient treated on Perfexion Gamma Knife using the Leksell Coordinate Frame in order to aid in analyzing the imaging metrics of the Image Guided Perfexion unit.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
1250
Inclusion Criteria
  1. At least 18 years old
  2. Ability to provide informed consent
  3. Any patient receiving single or multi-fraction stereotactic radiosurgery on the Perfexion Gamma Knife with image-guidance
Read More
Exclusion Criteria
  1. Age < 18 years old.
Read More

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
Setup variation in positioning between CT planning and treatmentThrough study completion, an average of 1 week

Measure intra-fraction setup variations between the CT planning and treatment position for the LCF and relocatable mask device

Setup variation of LCF and relocatable mask using CBCT ImagingThrough study completion, an average of 1 week

To quantify inter- and intra-fraction setup variations with the Leksell Coordinate Frame (LCF) and relocatable mask device as measured on CBCT and IFMM

Secondary Outcome Measures
NameTimeMethod
Target volume margins for brain metastasesThrough study completion, an average of 1 week

To determine evidence-based planning target volume margins for brain metastases patients undergoing treatment with single and multi-fraction stereotactic radiotherapy on the Perfexion™ Gamma Knife unit, as observed on volumetric cone-beam computed tomography (CBCT) scans

Trial Locations

Locations (1)

University Health Network

🇨🇦

Toronto, Ontario, Canada