INTACS® Prescription Inserts Used to Treat Patients with Keratoconus As a Humanitarian Use Device

University of Texas Southwestern Medical Center2 个研究点 分布在 1 个国家目标入组 25 人开始时间: 2011年1月最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
入组人数
25
试验地点
2
主要终点
Efficacy of INTACS prescription inserts to reduce astigmatism due to Keratoconus as determined by visual acuity examination.

研究概览

简要总结

The US food and Drug Administration (FDA) originally approved INTACS prescription inserts in April 1999 for the correction of low levels of nearsightedness (-1.00 to -3.00 diopters). Additional clinical data have shown that INTACS are safe for the treatment of keratoconus, in July 2004, FDA approved INTACS inserts for the treatment of keratoconus as a Humanitarian Use Device (FDA approval letter attached). The statute and the implementing regulation of FDA (21 CFR 814.124 (aj) require IRB review and approval before a HUD is used.INTACS prescription inserts are composed of two clear segments, each having an arc length of 150°, they are manufactured form a biomedical material called polymethylmethacrylate (PMMA) and are available in three thicknesses. Two INTACS inserts ranging from 0.250mm to 0.350mm may be implanted depending on the orientation of the cone and the amount of myopia and astigmatism to be reduced.

详细描述

The INTACS procedure is typically performed in an outpatient setting. The two tiny INTACS inserts are surgically placed into the periphery of the cornea through a tiny cut that is made on the cornea after numbing drops have been applied. A specially designed instrument creates a tunnel by separating the tissue layers in the outside periphery of the cornea, the INTACS inserts are placed into this tunnel where they remain. One or two ophthalmic sutures will be placed to close the incision. A postoperative care information booklet will be given to the patients; patients will be followed by means of postoperative appointments for up to 12 months after the surgery. The visits/testing schedules are listed below:

Pre-OR visit (1.5 hours): Visual Acuity (VA), Refraction, Topography, Keratometry, Glare Test. Mesopic Pupil Size, Pachymetry, Tonometry, Slit Lamp Exam and Contrast Sensitivity.

Surgery (30min): At Laser Center for Vision Care which is part of Aston and department of Ophthalmology.

Post-OR Day 1(10min): VA, Slit Lamp Exam.

Post-OR 1week (20min): Visual Acuity, Refraction, Topography, Tonometry, Slit Lamp Exam.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Who have experienced a progressive deterioration in their vision, such thot they can no longer achieve adequate functional vision on a daily basis with their contact lenses or spectacles; Who are 21 years of age or older; Who have clear central corneas; Who have a corneal thickness of 450 microns or greater at the proposed incision site; Who have corneal transplantation as the only remaining option to improve their functional vision.

排除标准

  • Who have abnormally thin corneas or who have a corneal thickness of 449 microns or less at the proposed incision site;
  • Patients with collagen vascular, autoimmune or immunodeficiency disease;
  • Pregnant or nursing patients;
  • Presence of ocular conditions, such as recurrent corneal erosion syndrome or corneal dystrophy, that my predispose the patient to future complications;
  • Patients who are taking on or more of following medications: isotretinoin (Accutane); amiodarone HCL (Cordarone).

结局指标

主要结局

Efficacy of INTACS prescription inserts to reduce astigmatism due to Keratoconus as determined by visual acuity examination.

时间窗: 12 Months

INTACS® prescription inserts are used to treat patients with Keratoconus as a Humanitarian Use Device. Efficacy of the INTACS inserts to reduce the effects of Keratoconus will be assessed using Visual Acuity to assess the effectiveness of INTACS surgery in regards decreasing level of astigmatism.

Efficacy of INTACS prescription inserts to reduce astigmatism due to Keratoconus as determined by refraction assessment.

时间窗: 12 Months

INTACS® prescription inserts are used to treat patients with Keratoconus as a Humanitarian Use Device. Efficacy of the INTACS inserts to reduce the effects of Keratoconus will be assessed using Refraction (pre-op refraction will be evaluated post-operatively) to assess the effectiveness of INTACS surgery in regards decreasing level of astigmatism.

Efficacy of INTACS prescription inserts to reduce other corneal aberrations due to Keratoconus as determined by corneal topography assessment.

时间窗: 12 Months

Corneal Topography evaluation to assess post-operative vs. pre-operative corneal surface curvature differences will be used to measure efficacy of this INTACS prescription inserts, and an evaluation whether there is a need for further interventions, including corneal transplant.

Efficacy of INTACS prescription inserts to reduce other corneal aberrations due to Keratoconus as determined by tonometry assessment.

时间窗: 12 Months

Tonometry will be used to measure efficacy of this INTACS prescription inserts, and an evaluation whether there is a need for further interventions, including corneal transplant.

Efficacy of INTACS prescription inserts to reduce other corneal aberrations due to Keratoconus as determined by slit lamp corneal examination.

时间窗: 12 Months

Slit Lamp corneal examination will be used to measure efficacy of this INTACS prescription, and an evaluation whether there is a need for further interventions, including corneal transplant.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Steven Verity

Professor of Medicine

University of Texas Southwestern Medical Center

研究点 (2)

Loading locations...