A Prospective Multi-center Randomized Study of the Difference in Diagnostic Yield Between EUS-FNA Needles With and Without a Side Port in Pancreatic Masses
试验速览
- 阶段
- 不适用
- 入组人数
- 200
- 试验地点
- 1
- 主要终点
- the overall diagnostic accuracy rate of both needles
研究概览
简要总结
For diagnosis of pancreatic tumors, endoscopic ultrasound (EUS) and EUS-guided fine needle aspiration (EUS-FNA) are well established techniques in clinical practice. We hypothesize that a FNA needle with a side port could improve the diagnostic yield. The aim of this prospective randomized study is to determine whether there is a difference in diagnostic yield in patients with pancreatic masses for evaluation.
详细描述
For diagnosis of pancreatic tumors, endoscopic ultrasound (EUS) and EUS-guided fine needle aspiration (EUS-FNA) are well established techniques in clinical practice. In the case of EUS, an ultrasonic transducer located at the tip of the echoendoscope allows the endoscopist to visualize the wall of gastrointestinal tract as a series of definable layers corresponding to histology, and also enables detailed images of areas outside of the digestive tract. EUS has a significant clinical impact because it allows assessment of submucosal GI lesions, loco-regional staging of gastrointestinal malignancy, tissue diagnosis by EUS-FNA and staging of pancreaticobiliary lesions, non-small-cell lung carcinoma, and mediastinal disease. In prospective trials, EUS-FNA has been clearly established to be an important diagnostic tool with excellent safety profile.
Olympus has recently made commercially available a new 22 gauge FNA needle with a side port at the needle tip to facilitate the process of FNA and increase the diagnostic yield. There have been preliminary unpublished retrospective data that suggested the yield might be raised. However, there are no prospective multicenter randomized controlled studies to ascertain the validity of the assumption. The aim of this prospective randomized study is to determine whether there is a difference in diagnostic yield between EZ-Shot 2 (model: NA-220H-8022) and EZ-Shot 2 with side port (NA-230H-8022) in patients with pancreatic masses for evaluation. We hypothesize that a FNA needle with a side port could improve the diagnostic yield.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Only
- 时间视角
- Prospective
入排标准
- 年龄范围
- 20 Years 至 90 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- 未提供
排除标准
- 未提供
结局指标
主要结局
the overall diagnostic accuracy rate of both needles
时间窗: assessment of diagnostic accuracy rate after 26 wks, then annually later
次要结局
未报告次要终点