MedPath

Irrigating Fluid and Blood Coagulation

Completed
Conditions
Blood Coagulation Disorder
Interventions
Other: A mixture of 2.7% sorbitol-0.54% mannitol solution
Registration Number
NCT03105180
Lead Sponsor
Seoul National University Bundang Hospital
Brief Summary

Irrigating fluid absorbed during the endoscopic surgery may alter whole blood coagulation. However, little is known about the dose-response relationships of hemodilution. The investigators have therefore performed the present study to measure the effect of a mixture of 2.7% sorbitol-0.54% mannitol solution on the coagulation pathway according to the hemodilution level using a rotational thromboelastometry (ROTEM®) tests.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
12
Inclusion Criteria
  • Healthy volunteers
  • age: 20 to 65 years
  • Body weight > 50 kg
  • Volunteers who provided informed consent
Exclusion Criteria
  • Hematologic disease
  • Anticoagulant medication

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
10% dilutionA mixture of 2.7% sorbitol-0.54% mannitol solutionBlood specimen which was diluted with 10% level using a mixture of 2.7% sorbitol-0.54% mannitol solution
20% dilutionA mixture of 2.7% sorbitol-0.54% mannitol solutionBlood specimen which was diluted with 20% level using a mixture of 2.7% sorbitol-0.54% mannitol solution
40% dilutionA mixture of 2.7% sorbitol-0.54% mannitol solutionBlood specimen which was diluted with 40% level using a mixture of 2.7% sorbitol-0.54% mannitol solution
Primary Outcome Measures
NameTimeMethod
FIBTEMduring the rotational thromboelastometry analysis/ an average of 1 hour

Fibrinolytic pathway values of rotational thromboelastometry analysis/ FIBTEM is s a proper noun which means the status of fibrinolytic coagulation pathway.

Secondary Outcome Measures
NameTimeMethod
INTEMduring the rotational thromboelastometry analysis/ an average of 1 hour

Intrinsic pathway values of rotational thromboelastometry analysis/ INTEM is a proper noun which means the status of intrinsic coagulation pathway.

EXTEMduring the rotational thromboelastometry analysis/ an average of 1 hour

Extrinsic pathway values of rotational thromboelastometry analysis/ EXTEM is a proper noun which means the status of extrinsic coagulation pathway.

Trial Locations

Locations (1)

Seoul National University Bundang Hospital

🇰🇷

Seongnam, Gyeonggi, Korea, Republic of

© Copyright 2025. All Rights Reserved by MedPath