Evaluation of Coronary Microvascular Dysfunction (EVACORY)
- Conditions
- Coronary Artery Disease
- Interventions
- Procedure: a new non-invasive imaging technique
- Registration Number
- NCT01995955
- Lead Sponsor
- University Hospital, Grenoble
- Brief Summary
The proposed study is to validate a new non-invasive imaging technique for evaluation of cardiac microciculation in coronary artery disease with a comparison with validated technique invasive, which is measure of index of myocardial resistance.
- Detailed Description
Coronary microvascular dysfunction is closely associated with coronary artery disease, it is an independent risk factor and predicts future coronary events or clinically manifest disease up to 10 years later.
Index of microcirculatory resistance (IMR) is a validated method to Assessment of the Coronary Microcirculation but this is an invasive technique.
In this study, we use a new mathematic technique from homogeneity analysis to provide precise, objective, automated quantification of perfusion heterogeneity at stress with new camera CZT SPECT. We compare the results with those of the measurement of IMR.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 45
- Stable angina
- Cadmium-zinc-telluride gamma camera SPECT
- Coronarography
- Pregnant woman
- Patient with terminal illness,
- Terminal Renal failure
- Allergy to iodine
- Contraindications for adenosine: Asthmatic patients, Second- or third-degree AV block without a pacemaker or sick sinus syndrome, Systolic blood pressure less than 90mm Hg, Recent use of dipyridamole or dipyridamole-containing medications, Methyl xanthenes such as aminophylline caffeine or theobromine block the effect of adenosine and should be held for at least 12 hours prior to the test, Known hypersensitivity to adenosine, Unstable acute myocardial infarction or acute coronary syndrome
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description a new non-invasive imaging technique a new non-invasive imaging technique a new non-invasive imaging technique for evaluation of cardiac microciculation in coronary artery disease
- Primary Outcome Measures
Name Time Method coronary microcirculation day 0 (inclusion) IMR was measured with commercially available software (St Jude Medical Systems) and thermodilution technique on a non-ischemic artery SPECT. Injections of 3 mL of room-temperature saline were made down the coronary artery, and the resting mean transit time (Tmn) was measured. CFR was calculated as resting Tmn divided by hyperemic Tmn. FFR was calculated by the ratio of Pd/Pa at maximal hyperemia.IMR was defined as distal coronary pressure multiplied by the hyperemic mean transit time (mm Hg • seconds, or units \[U\]). Myocardial Heterogeneity Index (Hi) was measured by an automated analysis developed in our research unit. Hi was finally calculated from images SPECT using a Markovian analysis. For this study Hi is given by the equation: Hi = Σm \[1/(1+m)2\]Pd(m).
- Secondary Outcome Measures
Name Time Method scintigraphy day 0 (inclusion) An FFR value of 0.80 or less identifies ischemia-causing coronary stenoses. The global summed stress score (SSS) was calculated by adding the scores of the 17 segments in the stress and rest images, respectively. Scans were considered as normal when SSS was \< 4.
Trial Locations
- Locations (1)
University Hospital of Grenoble
🇫🇷Grenoble, Isère, France