Refinement and Assessment of New MRI Technologies for Thoracic/ Cardiovascular Exams

University of Michigan1 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2009年1月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
100
试验地点
1
主要终点
New MRI Technologies

研究概览

简要总结

The purpose of the study is to improve chest MRI exams, eventually resulting in improvements in patient care.

详细描述

We will recruit patients to participate in the assessment of new MRI technologies designed to improve chest MRI exams that will result in improvements in patient care.

Several different MRI technologies will be evaluated. Specific evaluation of distinct technologies (eg. new head coil design, and new imaging sequence for the spine) may be evaluated simultaneously, or over non-overlapping periods in time.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Single Group
主要目的
Basic Science
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • If you are a male or a non-pregnant female patient, age 18 years or older, of any ethnic background presenting to MRI for a clinically-ordered chest MRI exam, you are eligible to participate in this study.
  • If you are a female of child bearing potential you will be questioned for the possibility of pregnancy. Pregnancy screening, if necessary, is performed routinely by ordering physicians prior to MRI scanning to confirm the patient is not pregnant.

排除标准

  • Patients who have electrically, magnetically or mechanically activated implants such as heart pacemaker, magnetic surgical clips, prostheses or implanted neurological stimulator.
  • Pregnant patients or patients who are nursing
  • Patients who are claustrophobic.

研究组 & 干预措施

Group 2 - Research MRI

Experimental

Subjects will have additional sequences and/or modification to MRI sequences.

干预措施: MRI-Research (Procedure)

Group 1 - Clinical MRI

Active Comparator

Clinically ordered MRI scan. Subjects will not have any additional sequences or modifications to their clinically ordered MRI

干预措施: MRI -Clinical (Procedure)

结局指标

主要结局

New MRI Technologies

时间窗: 3 years

Assessment of the new technologies will be quantified by a variety of performance and image quality/content measures. The appropriate set of measures will be selected based on specific features offered by each assessed technology, but will be drawn from the following quantities: 1. Scan speed: Scan speed is time required to set-up and run the new technique relative to the standard method. 2. Signal to noise: SNR (signal to noise ratio)is the ratio of average image intensity in target tissue relative to standard deviation of background areas (outside of body). This is a fundamental parameter used to quantify relative performance of new imaging sequences/hardware/software. 3. Contrast to noise: CNR (contrast to noise)is the difference in average image intensity between two target tissues relative to noise. This is a key descriptor to quantity lesion/tissue conspicuity, thus is used to characterize relative performance of new imaging sequence/hardware/software.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Jadranka Stojanovska, M.D., M.S.

Principal Investigator

University of Michigan

研究点 (1)

Loading locations...