MedPath

Anatomy-based Fitting in Unexperienced Cochlear Implant Users

Not Applicable
Recruiting
Conditions
Influence of Anatomy Based Frequency Mapping on Speech Outcomes and Hearing Related Measures
Interventions
Other: frequency distribution type
Registration Number
NCT05684393
Lead Sponsor
Dominik Riss
Brief Summary

The present study investigates CI users' potential differences in speech tests, other performance measures (i.e. pitch-matching, perception of timbre and melodic intervals, consonance perception), and patient-reported outcome (i.e. questionnaires) between the clinical fitting map and anatomy-based fitting in two groups of CI users (one with standard fitting and one with anatomy-based fitting).

Detailed Description

Not available

Recruitment & Eligibility

Status
RECRUITING
Sex
All
Target Recruitment
60
Inclusion Criteria
  • Post-lingual onset of severe to profound sensory-neural hearing loss in the implanted ear(s)
  • Post-OP CT scan of the CI electrode available
  • Subject implanted with MED-EL cochlear implant(s)
  • Subjects received a Flex28, FlexSoft and Standard electrode
  • Subject planned to receive a SONNET 2 or RONDO 3 audio processor on the newly implanted side
  • Audio processor not yet activated on the newly implanted side
  • The most apical active electrode contact has to be inserted at least 450°
  • Minimum of 10 active channels can be activated
  • Fluent in the language of the test centre
  • Signed and dated ICF before the start of any study-specific procedure
Exclusion Criteria
  • Lack of compliance with any inclusion criteria
  • EAS user (user of an EAS audio processor)
  • Implanted with C40+, C40X and C40C
  • Implanted with an ABI or Split electrode array
  • Anything that, in the opinion of the Investigator, would place the subject at increased risk or preclude the subject's full compliance with or completion of the study

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Standard fittingfrequency distribution type-
Anatomy based fittingfrequency distribution type-
Primary Outcome Measures
NameTimeMethod
Word recognition score (WRS)6 months

Percentage of correctly understood monosyllabic words from a list.

Secondary Outcome Measures
NameTimeMethod
Speech reception threshold (SRT)6 months

German matrix sentence test - speech to noise ratio in dB.

Pitch ranking6 months

Difference of the mean ranks for a set of frequencies presented to the tested CI ear and the reference ear.

Perception of timbre6 months

Visual Analog Scale ratings describing the difference in timbre between the tested CI ear and the reference ear when listening to audio.

Phoneme categorization6 months

Shape of the psychometric function describing the perception of the /s/-/ʃ/ continuum.

Consonance/difference rating6 months

The degree of modulation of the pleasantness-score across the individual intervals.

Trial Locations

Locations (1)

Medical University of Vienna

🇦🇹

Vienna, Austria

© Copyright 2025. All Rights Reserved by MedPath