Lung Ultrasonography for Detecting Extravascular Lung Water Overload in Intensive Care Patients Early After Surgery: a Preliminary Study

General Hospital Sveti Duh0 个研究点目标入组 60 人开始时间: 2015年4月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
60
主要终点
Inferior vena cava collapsibility index (IVCcl)

研究概览

简要总结

Aim. To investigate whether lung ultrasound can be used to detect extravascular lung water (EVLW) overload in the intensive care unit early after surgery.

Methods. This prospective study involved 60 patients without known cardiac or pulmonary diseases admitted to the intensive care unit at our hospital after elective abdominal or vascular surgery. The inferior vena cava collapsibility index (IVCcl), oxygen partial pressure (PaO2) and inspired oxygen pressure (FiO2) ratio (PaO2/FiO2), and appearance of B-lines ≤7 mm were determined upon admission to the intensive care unit and at 6, 12, and 24 h later. Fluid overload was defined as IVCcl ≤ 40% and the presence of B-lines ≤7 mm. Tissue oxygenation impairment was defined as a PaO2/FiO2 ratio < 200.

详细描述

After receiving general anesthesia, all patients received an endotracheal tube. After Co induction, anesthesia was maintained using a combination of inhalation anesthetic and intravenous drugs. Protective ventilation was combined with low flow. During surgery, all patients received Plasma Lyte 148 (pH 7.4; Viaflo, Baxter, Deerfield, IL, USA) at 6-8 ml/kg/h. Norepinephrine was administered at doses of 0.05-0.1 mcg/kg/min when needed to maintain mean arterial pressure over 60 mmHg. Packed red blood cells were used when hemoglobin concentration was ≤8.0 g/dl. At the end of anesthesia, participants were subjected to the recruitment maneuver. Patients older than 18 years admitted to intensive care unit after abdominal and vascular surgery with no cardiac or pulmonary diseases were included in the study.

.

After surgery, patients were admitted to the intensive care unit and given crystalloid Plasma Lyte at 1.5 ml/kg/h. At 24 h after surgery, all patients received the diuretic furosemide (20 mg).

Data on oxygen partial pressure and inspired oxygen pressure ratio (PaO2/FiO2), inferior vena cava collapsibility index (IVCcl) and occurrence of dense B-lines were monitored upon admission to the intensive care unit (baseline), as well as at 6, 12 and 24 h after admission. All measurements were done with the patients in supine position.

A decrease in PaO2/FiO2 ratio below 200 was taken to indicate a rise of extravascular lung water (EVLW) above 10 ml/kg (1-4); this cut-off indicates >20% shunting (5). IVCcl was measured based on changes in the diameter of the inferior vena cava during spontaneous breathing. IVCcl ≤40% was taken to indicate a rise in EVLW, since this cut-off reflects right arterial pressure of 10-15 mmHg (6). The appearance of "dense B-lines" on lung ultrasonography, defined as lines ≤7 mm apart, was also considered a sign of incipient increase in EVLW volume (7). Taking PaO2/FiO2 ratio as the reference method, we assessed the ability of dense B-lines, alone or in conjunction with IVCcl, to diagnose EVLW.

研究设计

研究类型
Observational
观察模型
Other
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • patients older than 18 years admitted to the intensive care unit following elective abdominal or vascular surgery

排除标准

  • known cardiac or pulmonary diseases
  • lung ultrasonography showed unilateral distribution.

结局指标

主要结局

Inferior vena cava collapsibility index (IVCcl)

时间窗: Baseline- upon admission to the ICU, 6, 12 and 24 hours after admission.

The maximum and minimum IVC diameters (cm) were calculated using ultrasound. IVCcl was measured using formula \[(maximum IVC diameter - minimum IVC diameter)/maximum IVC diameter\] based on changes in the diameter of the inferior vena cava during spontaneous breathing. IVCcl ≤40% was taken to indicate a rise in EVLW, since this cut-off reflects right arterial pressure of 10-15 mmHg.

oxygen partial pressure (PaO2) and inspired oxygen pressure (FiO2) ratio

时间窗: Baseline- upon admission to the ICU, 6, 12 and 24 hours after admission.

PaO2/FiO2 ratio will be measured from the arterial blood. A decrease in P/F ratio below 200 was taken to indicate a rise of EVLW above 10 ml/kg; this cut-off indicates \>20% shunting.

Dense B-lines

时间窗: Baseline- upon admission to the ICU , 6, 12 and 24 hours after admission.

The appearance of "dense B-lines" on lung ultrasonography, defined as lines ≤7 mm apart, was also considered a sign of incipient increase in EVLW volume