跳至主要内容
临床试验/NCT00159497
NCT00159497已完成4 期

Bone Remodeling Around HA-coated Acetabular Cups.

Northern Orthopaedic Division, Denmark1 个研究点 分布在 1 个国家目标入组 100 人开始时间: 1998年10月1日最近更新:
适应症

试验速览

阶段
4 期
状态
已完成
发起方
入组人数
100
试验地点
1
主要终点
Changes in bone mineral density around the hip prosthesis, measured by DEXA scanning

研究概览

简要总结

This study was designed to investigate the influence of HA-coating on bone remodeling around the cup in cementless THA.

100 patients gave informed consent to participate in a controlled randomized study between porous coated Trilogy® versus Trilogy Calcicoat®. The cup was inserted in press-fit fixation. The femoral component was a cementless porous coated titanium alloy stem (Bi-Metric®), with a modular 28 mm CrCo head. Effect parameters were Harris Hip Score (HHS) and Bone Mineral Density (BMD) determined by DEXA scanning.

Measurements revealed no difference between the two groups after 3 years, neither in clinical outcome nor in terms of periprosthetic bone density. Patients with Body Mass Index above normal regained more bone mineral than patients with normal weight. This finding supports the assumption that load is beneficial to bone remodeling. Advantages of better sealing of the bone-prosthesis interface, preventing polyethylene induced osteolysis, may still be anticipated for the 7 or 12 year follow-up examinations

详细描述

This study was designed to investigate the influence of HA-coating on bone remodeling around the cup in cementless THA.

100 patients gave informed consent to participate in a controlled randomized study between porous coated Trilogy® versus Trilogy Calcicoat®. The cup was inserted in press-fit fixation. The femoral component was a cementless porous coated titanium alloy stem (Bi-Metric®), with a modular 28 mm CrCo head. Effect parameters were Harris Hip Score (HHS) and Bone Mineral Density (BMD) determined by DEXA scanning.

Measurements revealed no difference between the two groups after 3 years, neither in clinical outcome nor in terms of periprosthetic bone density. Patients with Body Mass Index above normal regained more bone mineral than patients with normal weight. This finding supports the assumption that load is beneficial to bone remodeling. Advantages of better sealing of the bone-prosthesis interface, preventing polyethylene induced osteolysis, may still be anticipated for the 7 or 12 year follow-up examinations

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Participant)

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients eligible for cementless THA

排除标准

  • Medical conditions interfering with bone metabolism

结局指标

主要结局

Changes in bone mineral density around the hip prosthesis, measured by DEXA scanning

时间窗: 8-12 years

次要结局

  • Changes in hip performance, measured by Harris Hip Score(8-12 years)

研究者

发起方
Northern Orthopaedic Division, Denmark
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验