Clinical Validation of mμSORS for Non-invasive Blood Glucose Detection in Non-diabetic Subjects

Not Applicable
Completed
Conditions
Diabetes Mellitus
Interventions
Device: Multi-channel Microspatial Offset Raman Scattering Spectroscopy (mμSORS) for Noninvasive Blood Glucose Detection
Registration Number
NCT06512077
Lead Sponsor
Shanghai Jiao Tong University School of Medicine
Brief Summary

This is a single-center, open-label, prospective study. Blood glucose is measured at different time points during oral glucose tolerance test and hypoglucose clamp test in healthy subjects, using both venous plasma and multi-channel microspatial offset Raman scattering spectroscopy (mμSORS). Venous plasma glucose was set as gold standard. The two measurements were collected synchronously so as to calculate the mean absolute relative difference (MARD) and the consensus error grid (CEG). Accuracy of non-invasive blood glucose testing by mμSORS will be in-depth validated specifically in the 3-10 mmol/l glucose range.

Detailed Description

In order to clinically verify the accuracy and safety of non-invasive blood glucose measurement by the mμSORS technology specifically in the 3-10 mmol/l glucose range, this study will conduct oral glucose tolerance tests and hypoglucose clamp tests on healthy subjects at different time points during the tests. In oral glucose tolerance tests, there will be 9 points as follows: 0-min and post glucose-load 30-min, 60-min, 90-min, 120-min, 150-min, 180-min, 210-min and 240-min. While in hypoglucose clamp tests, blood glucose will be set at around 3.0-4.0mmol/l for about 1.5-2.0 hours, blood glucose will be detected every 10 minutes.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
30
Inclusion Criteria

Not provided

Exclusion Criteria

Not provided

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Clinical Validation of mμSORS for Noninvasive Blood Glucose Detection in healthy subjectsMulti-channel Microspatial Offset Raman Scattering Spectroscopy (mμSORS) for Noninvasive Blood Glucose DetectionEnrolled subjects will perform oral glucose tolerance test or hyperinsulin-hypoglucose clamp test. A measurement session of blood glucose consists of plasma sample and a measurement by mμSORS will be conducted synchronously.
Primary Outcome Measures
NameTimeMethod
Mean absolute relative deviation (MARD) of venous plasma glucose and glucose values measured by mμSORS at each time point of OGTT and hypoglucose clamp tests.2 months

Glucose will be measured using both intravenous sampling (plasma) and multi-channel microspatial offset Raman scattering spectroscopy (mμSORS) detection synchronously.

Consensus Error Grid (CEG) for venous plasma glucose and glucose values measured by mμSORS at each time point of OGTT and hypoglucose clamp tests.2 months

Glucose will be measured using both intravenous sampling (plasma) and multi-channel microspatial offset Raman scattering spectroscopy (mμSORS) detection synchronously.

Secondary Outcome Measures
NameTimeMethod
Incidence of Treatment-Emergent Adverse Events.2 months

Safety outcomes.

MARD for two measurement methods in different blood glucose ranges.2 months

Plasma glucose ranges 3.9-10.0 mmol/L and \<3.9 mmol/L.

Trial Locations

Locations (1)

Ruijin Hospital

🇨🇳

Shanghai, Shanghai, China