Clinical Validation of mμSORS for Noninvasive Blood Glucose Detection
- Conditions
- Diabetes MellitusMedical Device
- Interventions
- Device: Multi-channel Microspatial Offset Raman Scattering Spectroscopy (mμSORS) for Noninvasive Blood Glucose Detection
- Registration Number
- NCT05504005
- Lead Sponsor
- Shanghai Jiao Tong University School of Medicine
- Brief Summary
This is a single-center, open-label, prospective study. Blood glucose was measured at different time points during oral glucose tolerance testing in healthy subjects and patients with type 2 diabetes mellitus, using both venous plasma and multi-channel microspatial offset Raman scattering spectroscopy (mμSORS). Venous plasma glucose was set as gold standard.The two measurements were collected synchronously so as to calculate the mean absolute relative difference (MARD) and the consensus error grid (CEG). Accuracy of non-invasive blood glucose testing by mμSORS will be validated. MARD for two measurement methods in different blood glucose ranges and the effect of mμSORS on safety in the patient such as adverse events will also be assessed.
- Detailed Description
In order to clinically verify the accuracy and safety of non-invasive blood glucose measurement by the mμSORS technology, and to construct a model, this study will conduct oral glucose tolerance tests on healthy subjects and patients with type 2 diabetes at different time points during the OGTT. There will be 12 points as follows: 0-min and post glucose-load 10-min,30-min,60-min,90-min,120-min,150-min,180-min,210-min,240-min,270-min, and 300-min.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 35
Not provided
Not provided
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description Clinical Validation of mμSORS for Noninvasive Blood Glucose Detection Multi-channel Microspatial Offset Raman Scattering Spectroscopy (mμSORS) for Noninvasive Blood Glucose Detection Enrolled subjects will perform oral glucose tolerance test. A measurement session of blood glucose consists of plasma sample and a measurement by mμSORS will be conducted synchronously.
- Primary Outcome Measures
Name Time Method Mean absolute relative deviation (MARD) of venous plasma glucose and glucose values measured by mμSORS at each time point of OGTT. 2 months Glucose will be measured using both intravenous sampling (plasma) and multi-channel microspatial offset Raman scattering spectroscopy (mμSORS) detection synchronously.
Consensus Error Grid (CEG) for venous plasma glucose and glucose values measured by mμSORS at each time point of OGTT. 2 months Glucose will be measured using both intravenous sampling (plasma) and multi-channel microspatial offset Raman scattering spectroscopy (mμSORS) detection synchronously.
- Secondary Outcome Measures
Name Time Method Incidence of Treatment-Emergent Adverse Events 2 months Safety in the patients.
MARD for two measurement methods in different blood glucose ranges. 2 months Plasma glucose ranges 3.9-10.0 mmol/L, \<3.9 mmol/L and \>10.0 mmol/L.