Skip to main content
Clinical Trials/NCT02314845
NCT02314845
Completed
Not Applicable

Optimizing Intraoperative Mechanical Ventilation Using EIT-titrated PEEP

University of Sao Paulo General Hospital1 site in 1 country40 target enrollmentAugust 2014

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Pulmonary Atelectasis
Sponsor
University of Sao Paulo General Hospital
Enrollment
40
Locations
1
Primary Endpoint
Optimal PEEP value
Status
Completed
Last Updated
9 years ago

Overview

Brief Summary

The purpose of this randomized single center study is to determine the individual PEEP value that produces the best possible compromise of lung collapse and lung hyperdistention. Patients submitted to general anesthesia and mechanical ventilation during surgery (laparoscopy and open surgery) will participate. A PEEP titration procedure will be performed and the "optimal PEEP" value will be determined by electrical impedance tomography (EIT). An ultrasound will be used to record each step of the PEEP titration procedure in a sub-sample of patients. A total of 40 patients will be mechanically ventilated using physiological tidal volume (TV=6mL/kg of IBW) and fraction of inspired oxygen (FIO2) of 0.5 and will be randomized to one of two groups: "optimal PEEP" or a "low PEEP" (4cmH2O). Lung collapse and mechanics will be monitored by EIT throughout the intraoperative period. After extubation, a lung CT will be performed to evaluate the amount of lung collapse.

Detailed Description

Patients submitted to general anesthesia and mechanical ventilation commonly develop pulmonary atelectasis, which can cause adverse consequences either intraoperatively or postoperatively. The use of lower, more physiological tidal volumes (6-8 mL/Kg of ideal body weight) during the intraoperative period can minimize the risk of lung injury but may be associated with increased atelectasis. The application of PEEP can prevent the formation of atelectasis and minimize the resulting complications, but at the present time, there is no consensus on how to tailor the level of PEEP to best suit each patient. Electrical Impedance Tomography (EIT) is a portable non-invasive monitor that enables the analysis of lung function in a continuous mode. The aim of this study is to evaluate the use of Electrical Impedance Tomography (EIT), in the intraoperative period, as a tool for selecting "optimal PEEP" using a PEEP titration procedure, as well as assessing the evolution of pulmonary function during this period. The investigators will prospectively study a total of 40 adult patients (\> 18 years) divided into two subgroups: 20 laparoscopic surgery patients and 20 open surgery patients. After induction of anesthesia and neuromuscular blockade, all patients will be submitted to a recruitment maneuver in pressure-controlled ventilation (PCV) mode (PEEP = 20cmH2O, driving pressure = 20cmH2O, respiratory rate (RR) of 15 ipm and I:E ratio of 1:1) for 2 minutes followed by a decremental PEEP titration. The first step of the titration will start at a PEEP of 20 cmH2O and every 40 seconds PEEP will be decreased by 2 cmH2O, until a final PEEP of 4 cmH2O. A sub-sample of patients will have each step of the PEEP titration procedure recorded with an ultrasound and later evaluated by two different investigators. Optimal PEEP will be defined as that with the best compromise of atelectasis and overdistension as measured by EIT. Patients in each subgroup will be randomized to one of two ventilatory strategies: (1) PEEP chosen by the PEEP titration procedure; (2) PEEP set at 4 cmH2O. After a new recruitment maneuver PEEP will be set at the designated value and the patient will be ventilated with an inspired oxygen fraction of 50% or greater in order to maintain peripheral oxygen saturation (SpO2) \> 96%, a tidal volume of 6 mL/Kg and a respiratory rate to maintain an end tidal carbon dioxide (ETCO2) between 35-45. All patients will have their global and regional pulmonary mechanics monitored by EIT throughout the anesthetic procedure to assess the degree of pulmonary atelectasis. After extubation, patients will be referred to the Radiology Department for a chest CT.

Registry
clinicaltrials.gov
Start Date
August 2014
End Date
April 2016
Last Updated
9 years ago
Study Type
Interventional
Study Design
Parallel
Sex
All

Investigators

Responsible Party
Principal Investigator
Principal Investigator

Joaquim Edson Vieira

Associate Professor, Anesthesiology

University of Sao Paulo General Hospital

Eligibility Criteria

Inclusion Criteria

  • Patients submitted to general anesthesia for surgical procedure

Exclusion Criteria

  • Age \< 18 years
  • Thoracic surgery (any)
  • ASA grade III or IV
  • History of moderate/severe chronic obstructive pulmonary disease (COPD) or moderate/severe Asthma
  • Moderate/severe restrictive lung disease
  • Use of heart pacemaker

Outcomes

Primary Outcomes

Optimal PEEP value

Time Frame: 6 minutes

The PEEP value, for each patient, that produces the best possible compromise of lung collapse and lung hyperdistention during a PEEP titration procedure using EIT

Secondary Outcomes

  • Pulmonary atelectasis(2-5 hours)
  • Ultrasound evaluation(6 minutes)

Study Sites (1)

Loading locations...

Similar Trials