Effect of Automated Insulin Delivery on Early-stage Diabetic Complications
- Conditions
- Type 1 Diabetes
- Interventions
- Device: Medtronic MiniMed 780G with SmartGuard activationDevice: Medtronic MiniMed 780G without SmartGuard activation
- Registration Number
- NCT05477030
- Lead Sponsor
- University of Milan
- Brief Summary
Aim of this study is to verify the effects of an advanced HCL (Medtronic Minimed™ 780G) compared to SAP with PLGS on metabolic outcomes and markers of early microvascular damage in a population of adults with T1D previously treated with CSII. Evaluation of endothelial disfunction and autonomic neuropathy will also be performed.
- Detailed Description
New algorithms for the automation of insulin delivery (AID) are showing great benefit on glucose control in people with type 1 diabetes. Indeed, Hybrid closed loop (HCL) systems can improve HbA1c levels, percentage of time in defined glucose range, time below range and time over range, according to RCT and observational studies results. However, scientific evidences demonstrating potential benefits on the reduction of diabetes complications are limited regarding CSII or SAP with demonstrated reduction of cardiovascular mortality, improvement of albuminuria and peripheral nerve damage.
Data on AID effects on complications of diabetes are missing. In this study intermediate damage markers will be measured to assess potential effects of AID in comparison to sensor augmented pumps.
Recruitment & Eligibility
- Status
- UNKNOWN
- Sex
- All
- Target Recruitment
- 52
- Male and female patients
- T1D patients above 18 years in CSII treatment for at least 3 months
- HbA1c values between 6.0% and 9.5%
- Disease duration ≥ 2 years
- Written informed consent obtained from the patient
- Pregnancy
- Participation to other clinical trials
- A history of alcohol or drug abuse
- Advanced diabetic nephropathy defined as presence of albuminuria ≥ 300 mg/g or eGFR < 60 ml/min/1,73m2
- Proliferative Diabetic retinopathy or macular edema
- Established Atherosclerotic Cardiovascular Disease (ASCVD) or history of heart failure
- Presence of serious diseases or conditions which in the opinion of the Investigator makes patient non-eligible for the study
- Hypoglycemia Unawareness (Clarke score > 4)
- Patients unable to understand spoken and written Italian language
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description Study Group A (Intervention) Medtronic MiniMed 780G with SmartGuard activation Group treated with automated insulin delivery (advanced hybrid closed-loop) Study Group B (Control) Medtronic MiniMed 780G without SmartGuard activation Group treated with predictive low glucose suspend (sensor augmented pump - PLGS)
- Primary Outcome Measures
Name Time Method Time in glycemic range 70-180 mg/dl From Baseline to 26 weeks time spent by the patient in glucose range
Glycated Hemoglobin (HbA1c) From Baseline to 26 weeks percentage of hemoglobin glycosylated
- Secondary Outcome Measures
Name Time Method Early microangiopathic damage markers: osteopontin From Baseline to 26 weeks osteopontin (pg/ml)
Early microangiopathic damage markers: sTNFR-1/2 From Baseline to 26 weeks sTNFR-1/2 (pg/ml)
Early microangiopathic damage markers: B-2 microglobulin From Baseline to 26 weeks B-2 microglobulin (pg/ml)
Early microangiopathic damage markers: cystatin C From Baseline to 26 weeks cystatin C (ng/ml)
Early microangiopathic damage markers: neutrophil gelatinase-associated lipocalin From Baseline to 26 weeks neutrophil gelatinase-associated lipocalin (ng/ml)
Early microangiopathic damage markers: vWF levels From Baseline to 26 weeks vWF levels (ng/ml)
Endothelial disfunction From Baseline to 26 weeks Endothelial-dependent dilation (EDD) is considered a marker of dysfunctional abnormalities involved in early phases of atherosclerosis development. Changes in EDD precede structural changes and occurs in the preclinical phase of vascular disease.
In the present study endothelial dependent dilation is assessed by color Doppler evaluation of flow increase after hyperemia.
Trial Locations
- Locations (1)
ASST FBF Sacco
🇮🇹Milan, Italy