MedPath

Pulpal Blood Flow Changes Using SuperElastic 0.018-inch Nickel Titanium

Not Applicable
Completed
Conditions
Orthodontic Appliance
Interventions
Procedure: 0.014-inch NiTi on one side /0.018-inch NiTi on the other side
Procedure: 0.016-inch NiTi on one side /0.018-inch NiTi on the other side
Registration Number
NCT04378205
Lead Sponsor
Jordan University of Science and Technology
Brief Summary

to record pulpal blood flow (PBF) changes associated with using 0.018-inch Nickel Titanium (NiTi) as the first alignment archwire during fixed orthodontic treatment.

Detailed Description

Forty healthy patients with lower arch mild crowding with less than 2mm contact point displacement at any teeth were included. A split mouth study design was applied. Where each patient received 2 archwire sizes at one time joined in the midline by crimpable hook and applied in the lower arch.

Patients were assigned into one of 2 groups based on archwire sizes used. Group (1); 0.014-inch and 0.018-inch NiTi and Group (2); 0.016-inch and 0.018-inch NiTi. A Laser Doppler Flowmeter was used to measure PBF at different time intervals (T0-T5).

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
40
Inclusion Criteria
  • age 18-25 years
  • Class I skeletal malocclusion
  • Mild lower arches crowding.
  • Contact point displacement less than 2 mm.
  • No previous orthodontic treatment
Exclusion Criteria
  • Missing teeth
  • Poor oral hygiene
  • deep carious teeth
  • history of previous trauma
  • any medical conditions affecting blood vessels
  • smokers

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
0.014/0.018 NiTi arch wire0.014-inch NiTi on one side /0.018-inch NiTi on the other side0.014-inch NiTi on one side /0.018-inch NiTi on the other side (Nitinol SuperElastic 3M, Unitek) for initial alignment. This group included 20 patients
0.016/0.018 NiTi arch wire0.016-inch NiTi on one side /0.018-inch NiTi on the other side0.016-inch NiTi on one side / 0.018-inch NiTi on the other side (Nitinol SuperElastic 3M, Unitek) for initial alignment. This group included 20 patients
Primary Outcome Measures
NameTimeMethod
Pulpal blood flow changesup to 4 weeks

Measurements were taken by the use of Laser Doppler Flowmeter mm/s

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Dental Faculty/Jordan university of Science and Technology Dental Teaching Clinics

🇯🇴

Irbid, Jordan

© Copyright 2025. All Rights Reserved by MedPath