Skip to main content
Clinical Trials/NCT03544164
NCT03544164
Completed
N/A

Assessing Respiratory Rate and Tidal Volume Delivery During Manual Ventilation

Rush University Medical Center1 site in 1 country52 target enrollmentMay 7, 2018

Overview

Phase
N/A
Intervention
Not specified
Conditions
Advanced Cardiac Life Support, Cardiopulmonary Resuscitation, Tidal Volume, Manual Ventilation
Sponsor
Rush University Medical Center
Enrollment
52
Locations
1
Primary Endpoint
Tidal Volume delivery
Status
Completed
Last Updated
6 years ago

Overview

Brief Summary

Excessive minute ventilation for patients who experience cardiac arrest may cause pulmonary injury and decrease the overall effectiveness of cardiopulmonary resuscitation (CPR). Although clinicians are trained with the correct technique for manual ventilation, evidence still shows that clinicians tend to deliver a higher respiratory rate than recommended during CPR. Little is known about tidal volume delivery during CPR; either the amount of volume give or even the impact of tidal volume on the effectiveness of CPR. There are many factors that may influence variations of tidal volumes and RR during CPR. These factors include distractions in the room (noise/cross talk), inability to assess tidal volume delivery, anxiety, and stress of the situation. This study will evaluate tidal volume and respiratory rate (RR) delivery during a simulated CPR situation. Participants will be asked to provide care for an intubated adult patient in cardiac arrest, which will include all components of advanced cardiac life support training.

Detailed Description

This will be a cross-sectional study, conducted during regularly scheduled ACLS courses at Rush University Medical Center. Enrollment will be by random assignment as participants arrive for the ACLS course. Those that consent to the study will be informed that the investigator's study is to observe ACLS performance, but the exact parameters being measured will not be disclosed in an effort to mitigate any changes in behaviors. During the course of the study, groups will be assigned sequentially, and the first group to participate will be termed as "Group 1". Within the group, each participant will be assigned a letter to identify the sequence of rotation with the skills. For example, the first participant in group 1 to perform manual ventilation will be assigned the study identity of "1A". The second person in the first group will be "1B", and so on. During the ACLS megacode component of the ACLS training, each study participant will be given the opportunity to manually ventilate the simulated intubated adult patient, as per the normal rotation during a megacode. During the megacode, information will be collected via the NICO2 Respiratory Management System (Philips Respironics, Murrysville, Pennsylvania) that is attached to the endotracheal tube, which will be video recorded, as this system does not have function of data storage or downloaded. This is to assure each breath is captured so the study team can assure accuracy of data collection. None of the study participants will be video recorded. At the completion of the study, each participant will be debriefed on their performance and informed of the true nature of the study; which is to evaluate respiratory rate and tidal volume delivery during manual ventilation to an intubated patient during an ACLS rescue attempt.

Registry
clinicaltrials.gov
Start Date
May 7, 2018
End Date
July 7, 2019
Last Updated
6 years ago
Study Type
Observational
Sex
All

Investigators

Responsible Party
Principal Investigator
Principal Investigator

Brady Scott

Assistant Professor, Director of Clinical Education

Rush University Medical Center

Eligibility Criteria

Inclusion Criteria

  • 21 years old or older
  • licensed clinician, regardless of medical profession

Exclusion Criteria

  • Full-time, non-licensed students that have no completed their formal training program at Rush University

Outcomes

Primary Outcomes

Tidal Volume delivery

Time Frame: through study completion, an average of 1 year

Amount of volume delivered in milliliters per squeeze of the resuscitation device

Study Sites (1)

Loading locations...

Similar Trials