跳至主要内容
临床试验/NCT05140707
NCT05140707已完成不适用

The Effect of Virtual Reality on Pain, Anxiety, and Vital Signs of Oncology Patients Undergoing Port Catheter Implantation: A Randomized Controlled Study

Inonu University2 个研究点 分布在 1 个国家目标入组 139 人开始时间: 2019年9月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
139
试验地点
2
主要终点
Blood Pressure (Systolic and Diastolic)

研究概览

简要总结

This study aimed to determine the effect of virtual reality on pain, anxiety, and vital signs of oncology patients undergoing port catheter implantation. The study was carried out with 139 participants (69 intervention, 70 control) between September 2019 and January 2020. A patient identification form, state anxiety inventory, a table for vital signs, and a visual analog scale for pain severity were used for the data collection. Data were collected from the patients before, during, and after the implantation. In the intervention group, a virtual reality device, movies, and relaxing music were provided to the patients.

详细描述

To determine the effect of virtual reality (VR) on pain, anxiety, and vital signs of oncology patients undergoing port catheter implantation. The study was a randomized controlled study. The study was carried out with 139 participants (69 intervention, 70 control) between September 2019 and January 2020. Data were collected before, during, and after the implantation by using a patient identification form, State Anxiety Inventory (SAI), a table for vital signs, and a visual analog scale for pain severity. In the intervention group, a virtual reality device, movies, and relaxing music were provided and patients were instructed to use it during the implantation and when they felt pain after the implantation. Data of the study were analyzed with IBM SPSS v25.0.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Supportive Care
盲法
Single (Participant)

盲法说明

There wasn't a masking in the study.

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • aged 18 years and older, can communicate in Turkish, being diagnosed with cancer, and undergoing port catheter implantation.

排除标准

  • being have chronic pain or anxiety disorders, using any type of analgesic or anxiolytic, and diagnosed with epilepsy were excluded from the study. The patients who have a visual impairment or also excluded from the study. Patients diagnosed with brain cancer or have brain metastasis were excluded from the study considering the potential seizures. During the intervention, the interventions were ended for the patients who experienced headache or dizziness (two most common problems caused by VR) and data of these patients were not included in the analysis.

结局指标

主要结局

Blood Pressure (Systolic and Diastolic)

时间窗: Change from the baseline blood pressure at 4 hours

The blood pressure of the patients was assessed by using the Con-Tec CMS5100 device. The results presented as mmHg. The blood pressure measuring was administered for the patients in both groups.

Heart Rate

时间窗: change from baseline heart rate at 4 hours

Heart rates were assessed by using the Con-Tec CMS5100 device. Beat per minute was used for comparison. Heart rates were measured for both groups.

Pain Severity

时间窗: Change from baseline pain severity at 4 hours

A visual analog scale was used the examine the pain of the patients. Patients mark the severity of their experiences on 10 cm lines and the beginning of the line shows the lowest degree of the experience while the end of the line shows the highest. This scale is frequently used to determine the severity of the patient's pain. In this study, a 10 cm line was used to assess the severity of the patient's pain. While 0 reflects no pain, 10 reflects the highest severity of the pain. VAS was used for both groups before and after the port catheter implantation.

Anxiety

时间窗: Change from baseline anxiety levels at 4 hours

State anxiety inventory was used to examine the patients' anxiety. The scale was by Spielberger et al (1970). The Cronbach's Alpha internal consistency coefficients were range between .83 and .87. The State Anxiety Scale is a 20-item scale about how an individual feels at the moment. Originally, the scale consisted of two main domains, state anxiety, and trait anxiety. Only one of these two domains, state anxiety, was used in this study. The scores on the scale range between 20 and 80. Higher points reflect higher levels of anxiety. The scale was reported valid and reliable for Turkish society. The Cronbach's Alpha of the Turkish version was reported between 0.94 and 0.96. The scale was used for both groups before and after the port catheter implantation.

Respiratory Rate

时间窗: change from baseline respiratory rate at 4 hours

The respiratory rate was assessed by using the Con-Tec CMS5100 device. Respiration (inhalation and exhalation) per minute was used for comparison. The respiratory rate was measured for both groups.

O2 saturation

时间窗: change from baseline O2 saturation at 4 hours

O2 saturation was assessed by using the Con-Tec CMS5100 device. O2% were used for comparison. O2 Saturation was measured for both groups.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Runida Dogan

Assistant Professor

Inonu University

研究点 (2)

Loading locations...

相似试验