跳至主要内容
临床试验/NCT03576261
NCT03576261已完成不适用

Does Heart Failure Has Impact on Hemodynamic Stability During Anesthesia Induction

Umeå University2 个研究点 分布在 1 个国家目标入组 44 人开始时间: 2018年8月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
44
试验地点
2
主要终点
Incidence of severe blood pressure drops

研究概览

简要总结

The study aim is to investigate whether preoperative heart failure has impact on hemodynamic stability during anesthesia induction by target controlled infusion of anesthesia (TCI) in non-cardiac, non-morbidly obese surgery.

详细描述

40 individuals are enrolled to the study after signed informed consent at the day of surgery. The study participants are randomized (non-blinded) to preoperative fluid therapy (preoperative colloid fluid bolus at 6 ml/kg LBW, Gelofusine™, Fresenius Kabi AB, Sweden) or control (no preoperative fluids) before standardized TCI- induction of anesthesia. No other intravenous fluids before anesthesia induction.

Preoperative screening of biventricular systolic and diastolic function of the heart and level of venous return is implemented by transthoracic echocardiography approximately one hour before preoperative fluid therapy and anesthesia induction.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Other
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • age over 18 years
  • body mass index ≤ 35 kg/m2
  • electively scheduled for breast cancer surgery, endocrinologic surgery (thyroid, parathyroid) and general abdominal surgery

排除标准

  • instable angina pectoris
  • severe bronchial asthma
  • severe COPD
  • severe heart valve disease
  • severe renal failure
  • body mass index > 35 kg/m2

结局指标

主要结局

Incidence of severe blood pressure drops

时间窗: 20 minutes post anesthesia induction

Blood pressure drop below mean arterial pressure at 55 mmHg during anesthesia induction. Non-invasive blood pressures (systolic, mean and diastolic) are measured 5 minutes before anesthesia induction and thereafter every 5 minutes post-induction.

Incidence of blood pressure drops

时间窗: 20 minutes post anesthesia induction

Blood pressure drop below mean arterial pressure at 65 mmHg during anesthesia induction. Non-invasive blood pressures (systolic, mean and diastolic) are measured 5 minutes before anesthesia induction and thereafter every 5 minutes post-induction .

次要结局

  • Diastolic dysfunction and hemodynamic stability(20 minutes post anesthesia induction)
  • Venous return and hemodynamic stability(20 minutes post anesthesia induction)
  • Systolic heart failure and hemodynamic stability(20 minutes post anesthesia induction)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Tomi Myrberg

Principal investigator

Umeå University

研究点 (2)

Loading locations...

相似试验

Heart Failure and Hemodynamic Stability During... | 临床试验