PEEP FOR LUNG RECRUITMENT IN PRETERM INFANTS-EIT STUDY
- Conditions
- PreTerm NeonatePositive End Expiratory Pressure (PEEP)Lung RecruitmentElectrical Impedance Tomography (EIT)
- Registration Number
- NCT06705257
- Lead Sponsor
- South Tees Hospitals NHS Foundation Trust
- Brief Summary
Babies born early (under 32 weeks) are at risk of developing lung problems after birth. A major reason for this is that the lungs are not fully developed. Lungs of preterm babies will often collapse in between breathing due to lung immaturity. Applying gentle pressure, using nasal device through their nostril or through the breathing tube helps to prevent this lung collapse. This would help in air-oxygen going to lungs and also makes the babies breathing more comfortable. This gentle pressure is medically called as PEEP/CPAP and could be delivered by breathing machine (ventilator) and CPAP machine, collectively called as "continuous distending pressure (CDP)".
Those babies breathing on their own and receiving inadequate CDP would need more breathing support by placing them on breathing machine (ventilator). The longer the baby receives breathing machine support, higher chance of lung injury . Preterm infants who are already on breathing machine, providing sub optimal PEEP/CPAP could also lead to lung damage. Providing optimal PEEP/CPAP could prevent these negative outcomes. Currently there is not enough evidence to suggest optimal PEEP/CPAP in preterm infants. Neonatal units all around the world uses PEEP/CPAP ranging from 4 to 10cm H20 based on their unit practice. Currently available investigations provide limited one time information (e.g. Chest X-ray) regarding whether baby is receiving optimal PEEP/CPAP. Electrical Impedance Tomography (EIT) is a new technology which could provide better information regarding the pressure delivered. Also, this device would provide continuous information as if the clinicians are doing continuous chest X-ray but without any radiation. In this study, the team will assess the effect of different levels of PEEP/CPAP (4 to 10cm H20) on prevention of lung collapse using EIT. This would be studied in premature infants who are on breathing machine support and CPAP machine support.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- NOT_YET_RECRUITING
- Sex
- All
- Target Recruitment
- 30
Not provided
Not provided
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Primary Outcome Measures
Name Time Method Changes in EIT parameters 280minutes Changes in functional lung scores in percentage varying levels of CDP.
Changes in EIT 280 minutes Changes in silence spaces with varying levels of CDP.
- Secondary Outcome Measures
Name Time Method Secondary outcomes Total 280 minutes of study time Changes in oxygen saturation (SpO2 in percentage) during the study period.
Secondary outcome measure Total study time of 280 minutes Changes in carbon dioxide levels as measured by transcutaneous carbon dioxide levels (TCO2) in kilopascal.
Secondary outcome Total study time of 280minutes Changes in blood pressure (if measured) during the study procedure.
Related Research Topics