PEEP FOR LUNG RECRUITMENT IN PRETERM INFANTS-EIT STUDY

Not Applicable
Not yet recruiting
Conditions
PreTerm Neonate
Positive End Expiratory Pressure (PEEP)
Lung Recruitment
Electrical Impedance Tomography (EIT)
Registration Number
NCT06705257
Lead Sponsor
South Tees Hospitals NHS Foundation Trust
Brief Summary

Babies born early (under 32 weeks) are at risk of developing lung problems after birth. A major reason for this is that the lungs are not fully developed. Lungs of preterm babies will often collapse in between breathing due to lung immaturity. Applying gentle pressure, using nasal device through their nostril or through the breathing tube helps to prevent this lung collapse. This would help in air-oxygen going to lungs and also makes the babies breathing more comfortable. This gentle pressure is medically called as PEEP/CPAP and could be delivered by breathing machine (ventilator) and CPAP machine, collectively called as "continuous distending pressure (CDP)".

Those babies breathing on their own and receiving inadequate CDP would need more breathing support by placing them on breathing machine (ventilator). The longer the baby receives breathing machine support, higher chance of lung injury . Preterm infants who are already on breathing machine, providing sub optimal PEEP/CPAP could also lead to lung damage. Providing optimal PEEP/CPAP could prevent these negative outcomes. Currently there is not enough evidence to suggest optimal PEEP/CPAP in preterm infants. Neonatal units all around the world uses PEEP/CPAP ranging from 4 to 10cm H20 based on their unit practice. Currently available investigations provide limited one time information (e.g. Chest X-ray) regarding whether baby is receiving optimal PEEP/CPAP. Electrical Impedance Tomography (EIT) is a new technology which could provide better information regarding the pressure delivered. Also, this device would provide continuous information as if the clinicians are doing continuous chest X-ray but without any radiation. In this study, the team will assess the effect of different levels of PEEP/CPAP (4 to 10cm H20) on prevention of lung collapse using EIT. This would be studied in premature infants who are on breathing machine support and CPAP machine support.

Detailed Description

Not available

Recruitment & Eligibility

Status
NOT_YET_RECRUITING
Sex
All
Target Recruitment
30
Inclusion Criteria

Not provided

Exclusion Criteria

Not provided

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Primary Outcome Measures
NameTimeMethod
Changes in EIT parameters280minutes

Changes in functional lung scores in percentage varying levels of CDP.

Changes in EIT280 minutes

Changes in silence spaces with varying levels of CDP.

Secondary Outcome Measures
NameTimeMethod
Secondary outcomesTotal 280 minutes of study time

Changes in oxygen saturation (SpO2 in percentage) during the study period.

Secondary outcome measureTotal study time of 280 minutes

Changes in carbon dioxide levels as measured by transcutaneous carbon dioxide levels (TCO2) in kilopascal.

Secondary outcomeTotal study time of 280minutes

Changes in blood pressure (if measured) during the study procedure.