Hub Cleansing to Prevent Hub Infection

Rush University Medical Center1 个研究点 分布在 1 个国家目标入组 149 人开始时间: 2012年3月最近更新:
适应症
干预措施
相关药物

试验速览

阶段
不适用
状态
已完成
入组人数
149
试验地点
1
主要终点
Number of Central Venous Catheter Hubs With Internal Contamination

研究概览

简要总结

Central venous catheter infections are common preventable adverse events among hospital patients. Microbes may enter catheter hubs, also known as needleless connectors, and result in downstream contamination. This study aims to compare alcohol disinfection of catheter hubs to disinfection with chlorhexidine gluconate in alcohol, which has been proven to be a superior disinfectant at the site of central venous catheter insertion. Scrub duration of central venous catheter hubs will also be evaluated.

详细描述

A prospective randomized blinded crossover clinical trial will be performed in the medical intensive care unit at Rush University Medical Center. The intensive care unit will be divided into two regions (A&B). Hub disinfectants and duration of disinfection will be randomly assigned to these regions. After 1/2 of the study period, the agents will crossover, but the duration of scrubbing will remain the same, analogous to a 2 by 2 factorial design. Our primary endpoint will be internal contamination of hubs and catheters.

In February 2012 it was determined that the supplier of chlorhexidine and alcohol pads could not completely blind each pad. It was decided that a plain white sticker would be affixed to the front of each pad, but the safety information on the back of each pad would remain visible.

3/27/12-Internal hub contamination (yes/no)was clarified as the primary outcome.

On 5/10/12 a new sample size calculation adjusted the hub sample size needed to power the main effects based on more accurate information regarding the expected hub contamination rate. The expected hub contamination rate changed because of the more sensitive hub culture method that was adopted before the study began. This more sensitive method also allowed for a new secondary outcome of number of microbial colony forming units per hub.

The first crossover time selected was 6/11/12, prior to the midpoint of the study. This was done to try to improve a large imbalance in the group sizes.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Factorial
主要目的
Prevention
盲法
Double (Participant, Care Provider)

入排标准

年龄范围
16 Years 至 —(Child, Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Medical intensive care unit patients with non-tunneled central venous catheters

排除标准

  • Dialysis catheters
  • Antibiotic-impregnated catheters
  • Introducer sheaths
  • Tunneled catheters

研究组 & 干预措施

Alcohol with 5 second scrub

Experimental

70% isopropyl alcohol will be used to scrub catheter hubs for a duration of 5 seconds.

干预措施: 5 second scrub (Other)

Alcohol with 5 second scrub

Experimental

70% isopropyl alcohol will be used to scrub catheter hubs for a duration of 5 seconds.

干预措施: 70% isopropyl alcohol (Drug)

Alcohol with 15 second scrub

Experimental

70% isopropyl alcohol will be used to scrub catheter hubs for a duration of 15 seconds.

干预措施: 15 second scrub (Other)

Alcohol with 15 second scrub

Experimental

70% isopropyl alcohol will be used to scrub catheter hubs for a duration of 15 seconds.

干预措施: 70% isopropyl alcohol (Drug)

Chlorhexidine with 5 second scrub

Experimental

3.15% chlorhexidine/70% isopropyl alcohol will be used to scrub catheter hubs for a duration of 5 seconds.

干预措施: 5 second scrub (Other)

Chlorhexidine with 5 second scrub

Experimental

3.15% chlorhexidine/70% isopropyl alcohol will be used to scrub catheter hubs for a duration of 5 seconds.

干预措施: 3.15% chlorhexidine/70% isopropyl alcohol (Drug)

Chlorhexidine with 15 second scrub

Experimental

3.15% chlorhexidine/70% isopropyl alcohol will be used to scrub catheter hubs for a duration of 15 seconds.

干预措施: 15 second scrub (Other)

Chlorhexidine with 15 second scrub

Experimental

3.15% chlorhexidine/70% isopropyl alcohol will be used to scrub catheter hubs for a duration of 15 seconds.

干预措施: 3.15% chlorhexidine/70% isopropyl alcohol (Drug)

结局指标

主要结局

Number of Central Venous Catheter Hubs With Internal Contamination

时间窗: 15 months

This will be a qualitative outcome. It will be reported as "yes" or "no" for central venous catheter hub internal contamination. The number of hubs with internal contamination will be compared for the four study arms.

次要结局

  • Number of Contaminated Central Venous Catheter Tips(10 months)
  • Median Number of Microbial Colony Forming Units Per Hub Interior(15 months)