Brief Summary

The use of laryngeal mask airway or i-gel to manage airway may improve success rates, especially in difficult situations more than tracheal intubation.

Detailed Description

This study compares the insertion success rate and insertion time among the proceal laryngeal mask airway, i-gel, and tracheal tube. Following a short lecture, airway novices try to insert proceal laryngeal mask airway, i-gel, and tracheal tube into manikin with difficult laryngoscopy scenarios.

Study Design

Study Type
Interventional
Allocation
Non Randomized
Intervention Model
Factorial
Primary Purpose
Supportive Care
Masking
Single (Outcomes Assessor)

Eligibility Criteria

Sex
All
Accepts Healthy Volunteers
Yes

Inclusion Criteria

  • •medical student
  • •no experience of insertion using tracheal tube, i-gel, and laryngeal mask airway

Exclusion Criteria

  • •experience of insertion using tracheal tube, i-gel, and laryngeal mask airway

Arms & Interventions

tracheal tube

Active Comparator

Each novice performs tracheal intubation in difficult laryngoscopy scenario.

Intervention: tracheal tube (Device)

i-gel

Active Comparator

Each novice performs i-gel insertion in difficult laryngoscopy scenario.

Intervention: i-gel (Device)

proceal laryngeal mask airway

Active Comparator

Each novice performs proceal laryngeal mask airway insertion in difficult laryngoscopy scenario.

Intervention: proceal laryngeal mask airway (Device)

Outcomes

Primary Outcomes

the time of successful laryngeal mask, i-gel, or tracheal tube insertion attempt

Time Frame: intraoperative

A blinded observer records the time of successful laryngeal mask, i-gel, or tracheal tube insertion attempt.