MedPath

Erector Spinae Block Versus Transversus Abdominis Plane Block In Laparoscopic Bariatric Surgery

Not Applicable
Completed
Conditions
Erector Spinae Block
Bariatric Surgery Candidate
Interventions
Procedure: transversus abdominis block
Procedure: Erector spinae block
Device: Siemens Acuson x300 3-5MHz Ultrasound
Registration Number
NCT04417179
Lead Sponsor
Cairo University
Brief Summary

The purpose of this study to compare erector spinae block to transversus abdominis plane block in bariatric surgeries regarding analgesic efficacy and postoperative oxygenation and respiratory complications

Detailed Description

The erector spinae plane (ESP) block is an interfascial block proposed to provide analgesia for chronic pain and perioperative period. it can provide both visceral and somatic abdominal analgesia if the injection were performed at a lower thoracic level. ESP block is effective, easy to perform, and can be performed in a short time. Therefore, bilateral ESP block may have comparable or improved analgesic effect in upper and lower abdominal surgical procedures when compared to other suitable plane blocks.

Transversus abdominis plane (TAP) block technique is to reduce postoperative pain and is a part of current analgesic regimen for many abdominal surgeries . Moreover, it was found that posterior TAP block appears to produce more prolonged analgesia than the lateral TAP block. Ultrasound guided TAP block is a feasible, minimally invasive technique . It reduces the postoperative requirement of opioid analgesics, decreases the incidence and severity of postoperative nausea and vomiting, improves patient satisfaction, and allows early readiness for discharge postoperatively.

Both blocks is effective in reducing postoperative complication and need of analgesia , To our knowledge there is no comparative study between the two blocks to this population .

the investigators aim to compare the perioperative analgesic effect between TAP block and ES block in bariatric .

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
60
Inclusion Criteria
  • Patient age >18 <60
  • Obese patients ; Body mass index(BMI) 40-50 kg/m2
  • Both sexes
  • American Society of Anesthesiologists(ASA) physical status classes II and III
  • Patients scheduled for laparoscopic bariatric surgery i.e. sleeve gastrectomy and/or Roux-en-Y gastric bypass (RYGB)surgeries
Exclusion Criteria
  • Refusal of regional block
  • Patients with neurological, psychological disorders or those lacking cooperation
  • Patients scheduled for concomitant laparoscopic cholecystectomy or paraumbilical hernia repair or those with history of previous bariatric surgery or obstructive sleep apnea
  • Patients with anatomic abnormalities at site of injection, skin lesions or wounds at site of proposed needle insertion.
  • Patients with bleeding disorders defined as (INR >2) and/ or (platelet count <100,000/µL)
  • Patients with hepatic disease e.g. liver cell failure or hepatic malignancy or hepatic enlargement.
  • Patients who are allergic to amide local anesthetics.
  • Cases converted to open surgery will also be excluded from the study

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
TAP block groupBupivacaine 0.25% Injectable Solutionthe TAP block will be given by a high frequency linear ultrasound transducer of Siemens acuson x300 3-5MHz ultrasound . a blunted tip , 20-gauge, short bevel needle (Pajunk Sonoplex, Geisingen, Germany) will be used under direct ultrasound visualization, . After confirming the correct placement of the needle and the negative aspiration probe anaesthetic substance will be injected along the subcostal line in the transversus abdominis plane 20 ml 0.25% bupivacaine(10) , and the dissection of the plane was observed. The block will be performed bilaterally.
ESP groupBupivacaine 0.25% Injectable Solutionthe Erector Spinae block will be given by a high-frequency linear ultrasound transducer of Siemens acuson x300 3-5MHz ultrasound .A blunted tip , 20-gauge, short bevel needle (Pajunk Sonoplex, Geisingen, Germany) will be used under strict aseptic precautions until the tip is deep to erector spinae muscle, The block will be performed bilaterally by injecting 40 mL of 0.25% bupivacaine (20 mL into each side) into the fascial plane between the deep surface of the Erector Spinae muscle and the transverse processes of the lumbar vertebrae laterally
ESP groupSiemens Acuson x300 3-5MHz Ultrasoundthe Erector Spinae block will be given by a high-frequency linear ultrasound transducer of Siemens acuson x300 3-5MHz ultrasound .A blunted tip , 20-gauge, short bevel needle (Pajunk Sonoplex, Geisingen, Germany) will be used under strict aseptic precautions until the tip is deep to erector spinae muscle, The block will be performed bilaterally by injecting 40 mL of 0.25% bupivacaine (20 mL into each side) into the fascial plane between the deep surface of the Erector Spinae muscle and the transverse processes of the lumbar vertebrae laterally
TAP block grouptransversus abdominis blockthe TAP block will be given by a high frequency linear ultrasound transducer of Siemens acuson x300 3-5MHz ultrasound . a blunted tip , 20-gauge, short bevel needle (Pajunk Sonoplex, Geisingen, Germany) will be used under direct ultrasound visualization, . After confirming the correct placement of the needle and the negative aspiration probe anaesthetic substance will be injected along the subcostal line in the transversus abdominis plane 20 ml 0.25% bupivacaine(10) , and the dissection of the plane was observed. The block will be performed bilaterally.
TAP block groupSiemens Acuson x300 3-5MHz Ultrasoundthe TAP block will be given by a high frequency linear ultrasound transducer of Siemens acuson x300 3-5MHz ultrasound . a blunted tip , 20-gauge, short bevel needle (Pajunk Sonoplex, Geisingen, Germany) will be used under direct ultrasound visualization, . After confirming the correct placement of the needle and the negative aspiration probe anaesthetic substance will be injected along the subcostal line in the transversus abdominis plane 20 ml 0.25% bupivacaine(10) , and the dissection of the plane was observed. The block will be performed bilaterally.
ESP groupErector spinae blockthe Erector Spinae block will be given by a high-frequency linear ultrasound transducer of Siemens acuson x300 3-5MHz ultrasound .A blunted tip , 20-gauge, short bevel needle (Pajunk Sonoplex, Geisingen, Germany) will be used under strict aseptic precautions until the tip is deep to erector spinae muscle, The block will be performed bilaterally by injecting 40 mL of 0.25% bupivacaine (20 mL into each side) into the fascial plane between the deep surface of the Erector Spinae muscle and the transverse processes of the lumbar vertebrae laterally
Primary Outcome Measures
NameTimeMethod
efficacy of blockfirst 24 hours postoperative

The analgesic efficacy of erector spinae block versus TAP block assessed by visual analogue score(range from 1 denoted the least pain to 10 as the worst pain) in 24hr in laparoscopic bariatric surgery.

Secondary Outcome Measures
NameTimeMethod
failure ratefirst hour postoperatively

Failure rate in both groups

Trial Locations

Locations (1)

Faculty of Medicine

🇪🇬

Cairo, Egypt

© Copyright 2025. All Rights Reserved by MedPath