MedPath

Relationship Between Muscle Mass and Muscle Relaxation Time

Not Applicable
Completed
Conditions
Anesthesia
Interventions
Device: Inbody
Registration Number
NCT02617433
Lead Sponsor
Go Eun Bae
Brief Summary

Rocuronium block neuromuscular transmission at the neuromuscular junction, causing paralysis of the affected skeletal muscles. There have been several studies reported positive relationship between muscle mass and amount of neuromuscular junction. The purpose of this study is to find relationship between muscle mass and muscle relaxation time.

Detailed Description

Rocuronium block neuromuscular transmission at the neuromuscular junction, causing paralysis of the affected skeletal muscles. There have been several studies reported positive relationship between muscle mass and amount of neuromuscular junction. Until now, dose of rocuronium has been judged by patient's weight and height. However, height and weight do not represent exact muscle mass. The purpose of this study is to find relationship between muscle mass and muscle relaxation time. Measurement of muscle mass will be obtained using bioelectrical impedence analysis.

Recruitment & Eligibility

Status
COMPLETED
Sex
Male
Target Recruitment
42
Inclusion Criteria
  • All patient who undergo general anesthesia.
  • Male; weight 70-75kg , height 170-175cm
  • Female; weight 53-58kg , height 158-163cm
Exclusion Criteria
  • Liver and kidney disease
  • Any types of muscle disorder.
  • Metal materials or pacemaker in body

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
InbodyInbodyParticipant measure muscle mass by bioelectrical impedance analysis (Inbody 720, Seoul, Korea) after fast for eight hours.
Primary Outcome Measures
NameTimeMethod
ratio of result of first stimulus(T1) to result of supramaximal stimulation(T0)two hours

T1 and T0 is obtained by train of four which is commonly used neuromuscular monitoring device.

Secondary Outcome Measures
NameTimeMethod
completely suppression time of result of first stimulus(T1).ten minutes

T1 is obtained by train of four which is commonly used neuromuscular monitoring device.

Trial Locations

Locations (1)

Korea university anam hospital

🇰🇷

Seoul, Korea, Republic of