跳至主要内容
临床试验/NCT07524517
NCT07524517招募中不适用

NeoSHARK: Neonatal Study of Two-Handed Anatomical Versus Round facemasK Ventilation in Preterm and Term Infants; a Randomised Controlled Trial

University College Dublin1 个研究点 分布在 1 个国家目标入组 50 人开始时间: 2026年5月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
招募中
入组人数
50
试验地点
1
主要终点
Mask leak

研究概览

简要总结

When babies can't breathe effectively, we can use a facemask to give them breaths and oxygen. There are various types of facemasks that can be used, including round and anatomical (triangular) masks, depending on the preference of the hospital, but it is unclear if one is better for the baby. Both types of facemasks are recommended in international guidelines, without any advice whether one is better than the other. Previous studies published by our research group demonstrated that a variety of different masks are used around the hospitals in Ireland. If a lot of air is leaking around the mask, it means that the baby is not getting the full breathing support that we are trying to give. We currently do not have enough evidence to say which type of mask is better to reduce the risk of this potential leaking of air.

Recent studies have suggested that holding a mask with two hands (instead of one) is better in round facemasks. The combination of an anatomical mask and a two-handed hold has not yet been studied in babies.

In this study, we will compare two different facemasks (round and anatomical) when holding the mask on a baby's face with two hands to help them breathe. We will randomly allocate each baby to either a round mask or an anatomical (triangular) mask and we will measure how much air leaks out around the mask during each breath. We will do this in babies who are in the neonatal unit.

详细描述

Delivering effective facemask ventilation is an essential component of neonatal resuscitation. However, facemask leak of up to 60% in preterm neonates and airway obstruction are common and can be associated with ineffective ventilation of the baby and clinical instability (O'Currain 2019). Multiple characteristics may influence the effectiveness of facemask ventilation, such as operator technique, infant gestation, airway anatomy and tone, as well as facemask size and shape.

The Neonatal Resuscitation Programme (NRP) allows for either type of facemask as per local practice, without recommending a particular shape of that facemask. A recent national airway survey by our group demonstrated that 8/19 centres in Ireland use both anatomical and round facemasks in clinical practice, with 11 different sizes and shapes of facemasks in clinical use in neonatal units in Ireland. While studies to date have not found a difference between anatomical and round masks in neonatal manikins, these studies only included facemask ventilation delivered with a one-handed hold, rather than a two-handed hold. Emerging evidence, including benchtop and clinical data, suggests that a two-handed hold is superior to a one-handed hold in round facemasks. The combination of an anatomical mask and a two-handed hold has not yet been studied in a clinical setting.

This study will compare the measured leak in mask ventilation with a two-handed hold, delivered by a healthcare professional in the neonatal team, using an anatomical versus a round facemask with standardised mask size. The facemasks will be assessed by a randomised controlled trial, with the anatomical mask as the intervention and the round mask as the control. The population that will be studied is neonates in the neonatal intensive care unit (NICU), at any gestation, who the clinical team have decided to intubate. A member of the research team, who will provide an out-of-hours on call service, will attend the event. The relevant outcomes will be measured by the Monivent Neo100, which will be set up by the research team. Standardised mask size, as per local protocol, will be used, with the sensor module placed between the mask and the T-piece with an adaptor. The outcomes will assess the effectiveness of both the intervention and control, including ventilation parameters recorded by the Monivent Neo100 and the clinical stability of the patient. The primary outcome of this study is the percentage mask leak. A research team member will record data for primary and secondary outcomes. The event will be filmed for post-hoc video analysis. The outcome assessor will be blinded to the group allocation.This research project will take place over 10 months, with an interim analysis to ensure recruitment is projected to achieve sample size.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Supportive Care
盲法
Single (Outcomes Assessor)

盲法说明

This is an unblinded study as it is not possible to blind the provider to the type of facemask used. However, the operators will be blinded to the respiratory function monitor measurements feedback. This will be achieved by obscuring the colour sensor with an opaque covering and covering the Monivent screen. The outcome assessor will be blinded to the group allocation.

入排标准

性别
All
接受健康志愿者

入选标准

  • All term and preterm neonates in the neonatal unit who the clinical team have decided to intubate, with or without pre-medication, and who require mask ventilation prior to intubation attempt.

排除标准

  • Neonates with a congenital malformation that would impact mask seal will not be included.

研究组 & 干预措施

Intervention: Anatomical facemask

Experimental

Anatomical facemask with a two-handed hold while giving facemask ventilation. The operators may be any member of the neonatal team, who have undergone NRP certification. Standardised mask size for gestation and weight, as per local policy, will be used. Educational sessions, including practical training, will be carried out prior to commencing the study to ensure all potential operators are familiar with both types of facemasks.

干预措施: Intervention: Anatomical facemask (Device)

Control: Round facemask

Active Comparator

Round facemask with a two-handed hold while giving facemask ventilation. The operators may be any member of the neonatal team, who have undergone NRP certification. Standardised mask size for gestation and weight, as per local policy, will be used.

干预措施: Control: Round facemask (Device)

结局指标

主要结局

Mask leak

时间窗: Over a maximum of 20 minutes

Mask leak percentage, as measured by the Monivent Respiratory Function Monitor (RFM), with a minimum of 5 breaths collected. Maximum of 2 episodes of facemask ventilation will be collected, with values averaged.

次要结局

  • Lowest oxygen saturation(Over a maximum of 20 minutes)
  • Highest supplemental FiO2 used during facemask ventilation(Over a maximum of 20 minutes)
  • Positive inspiratory pressure during facemask ventilation(Over a maximum of 20 minutes)
  • Percentage of obstructed breaths during facemask ventilation(Over a maximum of 20 minutes)
  • Tidal volume during facemask ventilation(Over a maximum of 20 minutes)
  • Number of times facemask position is adjusted during facemask ventilation(Over a maximum of 20 minutes)
  • Duration of facemask ventilation(Over a maximum of 20 minutes)
  • Crossover to other handhold(Over a maximum of 20 minutes)
  • User opinion of mask hold(Over a maximum of 20 minutes)
  • Lowest heart rate(Over a maximum of 20 minutes)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验