跳至主要内容
临床试验/NCT04180605
NCT04180605Unknown不适用

The Value of FEops HEARTguideTM Patient-Specific Computational Simulation in the Planning of Percutaneous Left Atrial Appendage Closure With the AmplatzerTM AmuletTM Device (PREDICT-LAA)

Rigshospitalet, Denmark24 个研究点 分布在 7 个国家目标入组 200 人开始时间: 2020年1月6日最近更新:
适应症

试验速览

阶段
不适用
入组人数
200
试验地点
24
主要终点
Incomplete LAA closure and definite device-related thrombosis (DRT)

研究概览

简要总结

To ensure a successful percutaneous left atrial appendage (LAA) closure, it is important to select the correct size of the closure device used for each patient. To define and measure the size of the LAA, 2D transesophageal echocardiography (TEE) has been typically used. An increasing number of hospitals recently switched to measure the size of the LAA using a cardiac computed tomography (CT) scan. Although this CT scan helps to better define and measure the LAA, it is still difficult to determine the exact anticipated 'landing zone' or 'position' of the closure device. A novel strategy of preprocedural planning includes the use of preoperative computer simulations based on CT imaging (Feops HEARTguideTM), where the device is deployed with a computer simulation into the patient-specific LAA anatomy to provide the operator both optimal and suboptimal scenario's showing different sizes and positions of the closure device.

The aim of this study is to assess whether use of FEops HEARTguide computer simulations based on cardiac CT-imaging can contribute to a better preprocedural planning and improved procedural outcomes of percutaneous LAA closure procedures with an Amplatzer Amulet device.

The PREDICT-LAA trial will investigate the possible positive effect of a computer simulation using a CT scan of the LAA performed prior to the procedure. The hypothesis is that by using this new computer simulation, better planning of the intervention can be obtained.

详细描述

To prevent stroke in patients with non-valvular atrial fibrillation (NVAF) and contraindication(s) to oral anticoagulant therapy, percutaneous left atrial appendage (LAA) closure is increasily being chosen as an alternative therapeutic option. To obtain a successful percutaneous LAA closure, an accurate preoperative planning is required to understand the LAA morphology and assess the correct size and optimal position of the device. The instructions for use (IFUs) of the medical device providers are still based on two-dimensional transesophageal echocardiography, whereas an increasing number of centers have shifted towards LAA sizing and planning based on cardiac computed tomography (CT) images. Other options are also available for preoperative planning, among others the use of 3D printed LAA models. However, this has a number of disadvantages, among others complex logistics and the possible inaccuracy in terms of mechanical response of the printing material used for the 3D printed model.

Based on the FEops HEARTguideTM platform, a computational model for percutaneous LAA closure was developed and validated. The computer simulations are based on CT images, and can predict different possible LAA closure options for the patient, including optimal and suboptimal sizing and positioning of the LAA closure device. This can be achieved by modelling the mechanical interaction between the device and the 3D patient-specific LAA anatomy reconstructed from the CT images. The results are available as a web-based 3D-viewer and allow the physician to analyse the different device size and implant position options prior to the procedure.

The PREDICT-LAA trial aims to study the possible added value of FEops HEARTguideTM patient-specific computational simulation in the planning of percutaneous LAA closure with the AmplatzerTM AmuletTM device, with special focus on procedural safety and efficiency as well as on clinical outcomes.

The PREDICT-LAA study is a prospective, multicenter, randomized controlled trial. In total, 200 patients eligible for percutaneous LAA closure with an AmplatzerTM AmuletTM device (Abbott, USA) will be enrolled - 100 patients will be allocated to the computational simulation treatment arm and 100 patients to the standard treatment arm.

All participants will be treated according to the standard of care of the center - additionally, the preoperative planning for patients allocated to the computational simulation treatment arm will include a careful analysis of the computational simulation results provided by the FEops HEARTguideTM platform.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Supportive Care
盲法
Single (Outcomes Assessor)

入排标准

年龄范围
18 Years 至 100 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age above 18 years.
  • Patients with non-valvular atrial fibrillation (NVAF) who are referred to and approved for percutaneous LAA closure with an Amplatzer Amulet closure device, according to local practice and legislation.
  • Written informed consent.

排除标准

  • Reduced renal function with eGFR < 30 mL/min/1.73 m^
  • Iodine contrast allergy or other condition that prohibits cardiac CT imaging.
  • Suboptimal image quality of the pre-procedural cardiac CT-scan.

结局指标

主要结局

Incomplete LAA closure and definite device-related thrombosis (DRT)

时间窗: Post-procedural cardiac CT scan at 3 months after LAA closure

The percentage of patients with incomplete LAA closure (defined as any remaining contrast leakage into the LAA distal of the Amulet lobe) and/or a definite DRT at post-procedural cardiac CT imaging at three months after the procedure. Definite DRT is defined as "high-grade" hypo-attenuating thickening at the atrial surface of the closure device - as previously described by Korsholm et al., Circ Cardiovasc Interv, 2019.

次要结局

  • Procedural time(Periprocedural)
  • Contrast medium(Periprocedural)
  • Radiation exposure(Periprocedural)
  • Final position of the device(During post-procedural cardiac CT scan at 3 months after LAA closure)
  • Composite of all-cause death and thromboembolic event(12 months after randomization)
  • Number of repositioning(Periprocedural)
  • Different degrees of contrast leakage into the LAA(Post-procedural cardiac CT scan at 3 months after LAA closure)
  • Number of closure devices used(Periprocedural)
  • Procedural-related complications(Periprocedural and between randomization and within 7 days of the procedure)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Ole De Backer

Dr. Ole De Backer, MD, PhD, Consultant Interventional Cardiology

Rigshospitalet, Denmark

研究点 (24)

Loading locations...

相似试验