A Clinical Comparison of the Comfilcon A (Extended Range) XR Toric Multifocal and Omafilcon B Toric XR Multifocal Contact Lenses
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 24
- 试验地点
- 2
- 主要终点
- Overall Toric Lens Fit Acceptance
研究概览
简要总结
This study aims to compare the clinical performance and subjective acceptance of the comfilcon A and the omafilcon B soft contact lenses.
详细描述
This will be a randomized, subject-masked, crossover, bilateral study, controlled by cross comparison. Thirty subjects will use each lens type for two weeks in random sequence. Follow-up visits for each lens will be performed after two weeks of wear. Lenses will be worn on a daily wear basis.
The final optical design of comfilcon A contact lens was optimized to improve the quality and two further studies (CV-18-10 and CV-18-11) were conducted after completion of this study to evaluate the modified optical design.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Treatment
- 盲法
- Single (Participant)
入排标准
- 年龄范围
- 40 Years 至 70 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Subjects will only be eligible for the study if:
- •They are aged 40 - 70 years, inclusive.
- •They understand their rights as a research subject and are willing and able to sign a Statement of Informed Consent.
- •They are willing and able to follow the protocol.
- •They have successfully completed the non-dispensing study (C16-597) as the lenses to be worn on this study (C16-599) are predetermined from their participation on study C16-
- •They have a contact lens spherical prescription between +10.00 to -10.00D (Diopters) (inclusive).
- •They have astigmatism between of -0.75 and -5.75DC (based on the calculated ocular refraction) in each eye.
- •They have an Add component to their spectacle refraction (between +0.75 and
- •They can be satisfactorily fitted with the study lenses.
- •They can attain at least 0.30 logMAR binocular distance high contrast visual acuity with the study lenses within the available power range.
- •They have successfully worn soft contact lenses in the last two years.
- •They are willing to comply with the wear schedule (at least five days per week and for at least six hours per day).
- •They agree not to participate in other clinical research for the duration of this study.
- •They own a wearable pair of spectacles.
排除标准
- •Subjects will not be eligible to take part in the study if:
- •They have an ocular disorder which would normally contra-indicate contact lens wear.
- •They have a systemic disorder which would normally contra-indicate contact lens wear.
- •They are using any topical medication such as eye drops or ointment.
- •They have had cataract surgery.
- •They have had corneal refractive surgery.
- •They have any corneal distortion resulting from previous hard or rigid lens wear or have keratoconus.
- •They are pregnant or breast-feeding.
- •They have any clinically meaningful slit lamp findings contraindicating contact lens wear (e.g. ≥ Grade 3 finding of oedema, corneal neovascularisation, corneal staining, tarsal abnormalities, conjunctival injection, blepharitis/meibomian gland dysfunction) on the Efron classification scale or any other ocular abnormality that in the opinion of the investigator would contraindicate contact lens wear.
- •They have any infectious disease (e.g. hepatitis) which would, in the opinion of the investigator, contraindicate contact lens wear or pose a risk to study personnel; or they have any immunosuppressive disease (e.g. HIV).
- •They have a history of anaphylaxis or severe allergic reaction.
- •They have taken part in any other contact lens or care solution clinical trial or research, within two weeks prior to starting this study.
结局指标
主要结局
Overall Toric Lens Fit Acceptance
时间窗: 2 weeks
Overall toric lens fit acceptance is assessed for comfilcon A and omafilcon B lenses. Scale 0-4, 0=can't be worn, 1=Poor, 2=Fair, 3=Good, 4=optimum.
Comfort
时间窗: 2 weeks
Subjective ratings for comfort assessed. Scale 0-100, 0=cannot be worn, causes pain; 100=cannot be felt ever
Stability
时间窗: 2 weeks
Investigator's acceptance on overall stability for comfilcon A and omafilcon B lenses assessed using grading scale 0-4, 0=Totally unstable, can't be worn to provide acceptable vision correction for astigmatism, 4=Excellent orientation and optimum rotational.
Overall Satisfaction
时间窗: 2 weeks
Subjective ratings for overall satisfaction for comfilcon A and omafilcon B lenses assessed. Scale 0-100, 0=extremely dissatisfied, 100=extremely satisfied
Dryness
时间窗: 2 weeks
Subjective ratings for dryness assessed. Scale 0-100, 0=cannot be worn, extremely dry; 100=no dryness experienced at any time
Visual Fluctuation/ Stability
时间窗: 2 weeks
Subjective ratings for visual fluctuation/stability assessed. Scale 0-100, 0=totally unstable/ fluctuation/changing; 100=perfectly stable/not fluctuation/changing
Handling
时间窗: 2 weeks
Subjective ratings for handling difficulty assessed at 2 weeks. Scale 0-100, 0=very difficult, 100=very easy
Quality of Near Vision
时间窗: 2 weeks
Subjective ratings for quality of near vision. Scale 0-100, 0=extremely poor vision all of the time. cannot function, 100 - excellent vision all of the time.
Quality of Intermediate Vision
时间窗: 2 weeks
Subjective ratings for quality of intermediate vision. Scale 0-100, 0=extremely poor vision all of the time. cannot function, 100 - excellent vision all of the time.
Quality of Distance Vision
时间窗: 2 weeks
Subjective ratings for quality of distance vision. Scale 0-100, 0=extremely poor vision all of the time. cannot function, 100 - excellent vision all of the time.
Quality of Vision While Driving During the Night
时间窗: 2 weeks
Subjective ratings for quality of vision while driving at night. Scale 0-100, 0=extremely poor vision all of the time. cannot function, 100 - excellent vision all of the time.
Ghosting at Near
时间窗: 2 weeks
Subjective ratings for ghosting at near assessed at 2 weeks. Scale 0-100, 0=intolerable, 100=not noticeable.
Quality of Vision While Driving During the Day
时间窗: 2 weeks
Subjective rating for quality of vision while driving during the day. Scale 0-100, 0=extremely poor vision all of the time. cannot function, 100 - excellent vision all of the time.
Ghosting at Distance
时间窗: 2 weeks
Subjective ratings for ghosting at distance assessed at 2 weeks. Scale 0-100, 0=intolerable, 100=not noticeable.
次要结局
未报告次要终点
