跳至主要内容
临床试验/NCT03575988
NCT03575988Unknown不适用

Department of Solemn Scientific Research Platform in Liaoning University of Traditional Chinese Medicine

Guanlin Yang0 个研究点目标入组 180 人开始时间: 2018年7月3日最近更新:
适应症

试验速览

阶段
不适用
发起方
入组人数
180
主要终点
pulmonary function parameters(maximal voluntary ventilation,MVV,%)

研究概览

简要总结

Current knowledge: To the best of our knowledge, no studies have reported the correlation between pulmonary function and the vascular endothelial function in diabetic patients during the preclinical period. Indeed, diabetic nephropathy and retinopathy are the leading causes of end-stage renal failure and acquired blindness, respectively. However, when investigators treat patients with type 2 diabetes, investigators seldom consider the pulmonary vascular injury induced by glycemia. Experimental studies have shown that pulmonary function and Vascular endothelial function change during the preclinical stages of diabetic retinopathy. Researchers have already established that compared to healthy subjects, patients with type 2 diabetes have a reduced alveolar gas exchange capacity. The NO and ET-1 can be used to assess the Vascular endothelial function.

What this paper contributes to our knowledge: Regulating glycemia can improve Vascular endothelial function . This study suggests that detecting the NO and ET-1 would allow for the prediction of changes in pulmonary function during the preclinical stages of diabetic retinopathy and the degree of retinopathy in the future.

研究设计

研究类型
Observational
观察模型
Case Control
时间视角
Cross Sectional

入排标准

年龄范围
35 Years 至 70 Years(Adult, Older Adult)
性别
All
接受健康志愿者
是

入选标准

  • •symptoms of diabetes (thirst, polydipsia, diuresis, and unexplainable weight loss); 2) random blood sugar ≥11.1 mol/L, fasting plasma glucose ≥7.0 mol/L or an oral glucose tolerance test outcome (2-hour postprandial blood glucose) ≥11.1 mol/L; or 3) no symptoms of diabetes but either random blood sugar ≥11.1 mol/L or fasting plasma glucose ≥7.0 mol/L.

排除标准

  • •diagnosis of type 2 diabetes according to the guidelines of the American Diabetes Association;11 2) no history of smoking (never smoked), pulmonary disease or pulmonary infection (during the treatment or recovery period); 3) no hepatopathy, nephropathy, or gastrointestinal disease; and 4) a high likelihood of good compliance and the ability to visit our hospital for periodic assessments. The exclusion criteria were as follows: 1) diagnosis of type 1 diabetes; 2) pregnancy and/or active lactation; 3) intensive care with insulin treatment; 4) renal inadequacy, hypohepatia, or heart disease; 5) pneumonia, influenza (during the treatment or recovery period), phthisis or other pulmonary infection; 6) presence of multiple pulmonary cysts, bullae of the lung, or diffuse pulmonary calcifications confirmed via CT; 7) combined diabetic retinopathy and hypertension (for which antihypertensive drugs are used); 8) aneurysm, dissection of aorta; 9) inadequate control of serum lipid parameters by cholesterol-lowering drugs; 10) body mass index ≥32; and 11) the use of systemically injected glucocorticoids within 3 months prior to our study.

结局指标

主要结局

pulmonary function parameters(maximal voluntary ventilation,MVV,%)

时间窗: one week

Pulmonary function tests were performed using a spirometer. We used the ratio of measured values to the expected values, % of predicted value, to eliminate the influence of age, height, and weight. Before testing, subjects remained sitting at quiet rest for at least 30 min, pulmonary function tests were performed 3 times and the best of 3 acceptable readings was used in the analysis. Spirometry and analysis of pulmonary function were performed by trained professionals.

pulmonary function parameters(diffusing capacity for carbon monoxide of lung,DLCO,%)

时间窗: one week

Pulmonary function tests were performed using a spirometer. We used the ratio of measured values to the expected values, % of predicted value, to eliminate the influence of age, height, and weight. Before testing, subjects remained sitting at quiet rest for at least 30 min, pulmonary function tests were performed 3 times and the best of 3 acceptable readings was used in the analysis. Spirometry and analysis of pulmonary function were performed by trained professionals.

pulmonary function parameters(vital capacity,VC,%)

时间窗: one week

Pulmonary function tests were performed using a spirometer. We used the ratio of measured values to the expected values, % of predicted value, to eliminate the influence of age, height, and weight. Before testing, subjects remained sitting at quiet rest for at least 30 min, pulmonary function tests were performed 3 times and the best of 3 acceptable readings was used in the analysis. Spirometry and analysis of pulmonary function were performed by trained professionals.

pulmonary function parameters(forced vital capacity,FVC,%)

时间窗: one week

Pulmonary function tests were performed using a spirometer. We used the ratio of measured values to the expected values, % of predicted value, to eliminate the influence of age, height, and weight. Before testing, subjects remained sitting at quiet rest for at least 30 min, pulmonary function tests were performed 3 times and the best of 3 acceptable readings was used in the analysis. Spirometry and analysis of pulmonary function were performed by trained professionals.

pulmonary function parameters(total lung capacity,TLC,%)

时间窗: one week

Pulmonary function tests were performed using a spirometer. We used the ratio of measured values to the expected values, % of predicted value, to eliminate the influence of age, height, and weight. Before testing, subjects remained sitting at quiet rest for at least 30 min, pulmonary function tests were performed 3 times and the best of 3 acceptable readings was used in the analysis. Spirometry and analysis of pulmonary function were performed by trained professionals.

pulmonary function parameters(forced expiratory volume in 1 second/ forced vital capacity,FEV1/FVC,%)

时间窗: one week

Pulmonary function tests were performed using a spirometer. We used the ratio of measured values to the expected values, % of predicted value, to eliminate the influence of age, height, and weight. Before testing, subjects remained sitting at quiet rest for at least 30 min, pulmonary function tests were performed 3 times and the best of 3 acceptable readings was used in the analysis. Spirometry and analysis of pulmonary function were performed by trained professionals.

pulmonary function parameters(peak expiratory force,PEF,%)

时间窗: one week

Pulmonary function tests were performed using a spirometer. We used the ratio of measured values to the expected values, % of predicted value, to eliminate the influence of age, height, and weight. Before testing, subjects remained sitting at quiet rest for at least 30 min, pulmonary function tests were performed 3 times and the best of 3 acceptable readings was used in the analysis. Spirometry and analysis of pulmonary function were performed by trained professionals.

pulmonary function parameters(diffusing capacity for carbon monoxide of lung/unit volume,DLCO/VA,%)

时间窗: one week

Pulmonary function tests were performed using a spirometer. We used the ratio of measured values to the expected values, % of predicted value, to eliminate the influence of age, height, and weight. Before testing, subjects remained sitting at quiet rest for at least 30 min, pulmonary function tests were performed 3 times and the best of 3 acceptable readings was used in the analysis. Spirometry and analysis of pulmonary function were performed by trained professionals.

pulmonary function parameters(forced expiratory volume in 1 second,FEV1,%)

时间窗: one week

Pulmonary function tests were performed using a spirometer. We used the ratio of measured values to the expected values, % of predicted value, to eliminate the influence of age, height, and weight. Before testing, subjects remained sitting at quiet rest for at least 30 min, pulmonary function tests were performed 3 times and the best of 3 acceptable readings was used in the analysis. Spirometry and analysis of pulmonary function were performed by trained professionals.

次要结局

  • Vascular endothelial function(nitrogen oxide,NO,μmol /L)(one week)
  • Vascular endothelial function(endothelin-1,ET-1,μmol /L)(one week)

研究者

发起方
Guanlin Yang
申办方类型
Other
责任方
Sponsor Investigator
主要研究者

Guanlin Yang

Guan-lin Yang is the presidentg and full Clinical professor(Cardiovascular medicine) of Liaoning University of Traditional Chinese Medicine

Liaoning University of Traditional Chinese Medicine

相似试验