MedPath

Evaluation of the Rectal Reflex Using Anal Acoustic Reflectometry

Completed
Conditions
Pelvic Floor Dysfunction
Registration Number
NCT02782377
Lead Sponsor
Manchester University NHS Foundation Trust
Brief Summary

Anal Acoustic Reflectometry (AAR) is a reliable and reproducible technique that has been studied in our department over the last 6 years. Sound waves pass into a balloon placed in the anal canal and are used to measure the cross-sectional area. By gradually increasing and decreasing the pressure in the balloon the investigators can measure the pressure at which the cross-sectional area starts to increase and decrease, and the anal canal starts to open and close. This assessment mimics the natural opening and closing of the anal canal and the effect of squeezing the muscles.

The gold standard investigation of the anal sphincter muscles has been manometry which measures anal canal pressure at rest and during squeeze. However, it has limitations. In previous studies AAR has shown promise in the assessment of faecal incontinence and, that unlike manometry, it has been able to distinguish between different types of incontinence.

The Recto-anal Inhibitory Reflex (RAIR) is a normal response when the rectum fills with faeces, fluid or air, whereby there is a change in the pressures within the anal canal to determine the type of contents. This can be absent or altered in patients who have difficulty in opening their bowels. The RAIR is currently measured by anal manometry using a 4.9mm catheter, resulting in an anal canal which is already partially opened prior to the measurement, and potentially distorted.

AAR is considered a catheter free technique as the balloon has a cross-sectional area of only 0.4mm2 when collapsed. The investigators propose to measure the RAIR using a 1.7mm diameter catheter alongside the AAR balloon to determine the effect that its placement has on the recorded parameters of AAR. This aims to improve our understanding of the opening and closing of the anal canal in response to distension of the rectum.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
40
Inclusion Criteria
  1. Adults over 18 years old
  2. Have capacity to consent to the study
  3. Patients with pelvic floor dysfunction.
Exclusion Criteria
  1. Minors under the age of 18 years old
  2. Patients who lack capacity to consent
  3. Patients with known rectal tumours and proctitis
  4. Asymptomatic patients

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
Opening Pressureduring single study visit- measurement taken prior to balloon inflation and post balloon inflation

Measurements of differences in Opening pressure (Op - cm H2O) as measured by the AAR catheter.

These measurements are taken at baseline with the rectal balloon collapsed (Pre-RAIR) and after inflation of 100mls air into rectal balloon (Post-RAIR).

Closing Pressureduring single study visit- measurement taken prior to balloon inflation and post balloon inflation

Measurements of differences in Closing Pressure (Cp - cm H2O) as measured by the AAR catheter. These measurements are taken at baseline with the rectal balloon collapsed (Pre-RAIR) and after inflation of 100mls air into rectal balloon (Post-RAIR).

Opening Elastanceduring single study visit- measurement taken prior to balloon inflation and post balloon inflation

Measurements of differences in Opening Elastance (Oe - cm H2O/mm2) as measured by the AAR catheter. These measurements are taken at baseline with the rectal balloon collapsed (Pre-RAIR) and after inflation of 100mls air into rectal balloon (Post-RAIR).

Closing Elastanceduring single study visit- measurement taken prior to balloon inflation and post balloon inflation

Measurements of differences in Closing Elastance (Ce - cm H2O/mm2) as measured by the AAR catheter. These measurements are taken at baseline with the rectal balloon collapsed (Pre-RAIR) and after inflation of 100mls air into rectal balloon (Post-RAIR).

Hysteresisduring single study visit- measurement taken prior to balloon inflation and post balloon inflation

Measurements of differences in Hysteresis (%) as measured by the AAR catheter. These measurements are taken at baseline with the rectal balloon collapsed (Pre-RAIR) and after inflation of 100mls air into rectal balloon (Post-RAIR).

Hysteresis is the extent of energy expenditure during opening and closing of the anal canal and represents the difference between opening and closing pressure and is expressed as a percentage

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

University Hospital of South Manchester

🇬🇧

Manchester, Greater Manchester, United Kingdom

© Copyright 2025. All Rights Reserved by MedPath