跳至主要内容
临床试验/NCT00126204
NCT00126204已完成不适用

Adjunctive Treatment With Doxycycline in Endovascular Aneurysm Repair

The Foundation for Barnes-Jewish Hospital2 个研究点 分布在 1 个国家目标入组 75 人开始时间: 2004年3月1日最近更新:
适应症
相关药物

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
75
试验地点
2
主要终点
Change in aortic measurements by > 2 mm on 2 consecutive scans

研究概览

简要总结

The durability of endovascular aneurysm repair (EVAR) has been limited by development of endoleaks which may be secondary to progressive aortic degeneration by matrix metalloproteases (MMP). Doxycycline is a known inhibitor of the MMP family of enzymes in aneurysms. The investigators propose a randomized, controlled trial of adjuvant doxycycline therapy with EVAR to determine its effects on re-intervention, aneurysm shrinkage and serum markers of aneurysmal degeneration.

详细描述

Patients will be consented and enrolled at the time of their clinic visit or admission to the hospital for a planned EVAR, in accordance with institutional review board guidelines. Demographic, risk factor and medication regimen data will be obtained from the patient's clinical chart. Patients will be randomized to doxycycline therapy (100 mg taken twice daily) or a placebo. The patients will receive their first dose of study medication on the day following surgery, and continue the study therapy for 6 months.

Plasma and serum will be obtained at the time of enrollment (baseline), and at each post-operative follow-up visit during the study as outlined above. Aliquots will be stored at -80ºC until assayed. Measurements of the circulating markers will be performed by commercially available assays for plasma MMP-9 (R&D Systems, Minneapolis, MN), serum IL-6 (R&D Systems) , IL-8 (R&D Systems), IFN-gamma (R&D Systems), and CRP (Bio-Check, Burlingame, CA) Data will be collected from the pre-operative and all post-operative CT scans regarding maximal aneurysm diameter and transverse neck diameter at 5 mm, 10 mm and 15 mm below the takeoff of the lowest renal artery. All documented endoleaks and their clinical type will be recorded, as will any re-intervention related to the graft or aneurysm.

The primary end-points of the study related to aneurysm measurements will be an increase or decrease in any of the diameter measurements of the aorta by 2 mm or more on 2 consecutive CT scans or a change of 5 mm or more on any single scan. Of the circulating markers, an additional primary endpoint will be a 50% reduction in baseline MMP-9 after endografting. Secondary endpoints will be significant reductions over baseline in circulating IL-6, IL-8, IFN-γ, and CRP. An a priori power analysis indicates that at 6 months, reductions in circulating levels of these markers by 50% can be detected with a β-error of less than 0.1 and α-error of less than 0.05.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Double

入排标准

年龄范围
50 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Presence of an abdominal aortic aneurysm (AAA) with a maximum diameter of > or = 4.5 cm
  • Planned aneurysm exclusion with endoluminal stent graft (any brand)

排除标准

  • Known malignancy not to include prostate cancer or any history of cancer that has not had a recurrence in the last 5 years.
  • Hypersensitivity to doxycycline or any of its components
  • Pregnancy
  • Ruptured AAA
  • Extension of covered portion of the graft above the renal arteries
  • Previous endoluminal aneurysm repair

结局指标

主要结局

Change in aortic measurements by > 2 mm on 2 consecutive scans

Change in aortic measurement by > 5 mm on a single scan

50% reduction in baseline plasma MMP-9 at 6 months

次要结局

  • Significant reductions at 6 months in serum interleukin-6 (IL-6)
  • Significant reductions at 6 months in serum IL-8
  • Significant reductions at 6 months in serum interferon-gamma
  • Significant reductions at 6 months in serum C-reactive protein

研究者

发起方
The Foundation for Barnes-Jewish Hospital
申办方类型
Other

研究点 (2)

Loading locations...

相似试验