Does the Use of Hemostatic Clips During the Tumor Resection Step Reduce Blood Loss During Robot-assisted Partial Nephrectomy?
- Conditions
- Blood LossRenal CancerKidney Cancer
- Interventions
- Procedure: Patial nephrectomy
- Registration Number
- NCT04388917
- Lead Sponsor
- Centre Hospitalier Universitaire de Nice
- Brief Summary
One challenge of robot-assisted partial nephrectomy (RAPN) is to reduce operative blood loss. Partial nephrectomy (PN) is a complex surgery that is being made easier by robotic assistance. In this study, we determined whether the use of hemostatic clips during the tumor resection step reduced blood loss during robot-assisted partial nephrectomy. Methods: In this retrospective study, we included all consecutive patients who underwent RAPN in our university hospital from 2017 to 2019. Three experienced surgeons performed the surgery. One surgeon used Hemo-lock hemostatic clips during tumor resection to prevent bleeding, and two did not. Blood loss in the two groups was compared as the primary endpoint. The duration of clamping, operative time, complications, surgical margins, transfusions, serum creatinine and hemoglobin were compared as secondary endpoints. Results: 53 patients were included, 36 in the No-clip group and 17 in the Clip group. Our two groups were comparable for age, weight, Charlson score, tumor size and RENAL score. There was a significant difference between the two groups for median blood loss 50 mL in the Clip group versus 300 mL in the No-clip group (p = 0.0001), whereas median operating time was shorter in the No-clip group, 140 min versus 180 min for the Clip group (p = 0.044). No other criterion showed a significant difference. The use of Hemo-lock during the tumor resection step in RAPN reduced blood loss without impairing renal function. Larger studies are still needed to confirm our findings.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 53
- all consecutive patients who underwent Robot Assisted Partial Nephrectomy
- patient off clamping or partial clamping
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Arm && Interventions
Group Intervention Description No Clip group Patial nephrectomy No Hemo-lock hemostatic clips used during tumor resection Clip Group Patial nephrectomy Use of Hemo-lock hemostatic clips during tumor resection to prevent bleeding
- Primary Outcome Measures
Name Time Method Blood loss in the two groups was compared 3 years It was mesured during the surgery by amount of blood drawn
- Secondary Outcome Measures
Name Time Method operative time 3 years duration from the begining to the end of the surgery
duration of clamping 3 years time between the clips set and remove during the surgery for patient of clip group
incidence of complications 3 years rate of complication after surgery