Changing in Skin Physiology After Microdroplet Placement of Stabilized Hyaluronic Acid in Aging Faces

Phase 4
Completed
Conditions
Aging
Interventions
Device: Restylane Vital
Registration Number
NCT02312154
Lead Sponsor
Konkuk University Hospital
Brief Summary

IMPORTANCE Skin rejuvenation can be achieved effectively and safely by injection of a stabilized hyaluronic acid (HA)-based gel of nonanimal origin (NASHA) injection using a stamp-type electronic multineedle injector.

OBJECTIVE To determine the efficacy and safety of NASHA using a stamp-type electronic multineedle injector, and if changes in skin physiology occur earlier than in previous trials.

DESIGN, SETTING, AND PARTICIPANTS Twenty-five patients were recruited to this single-center, evaluator-blinded, prospective, balanced (1:1), split-face randomized clinical trial.One dermatologist who was blinded as to the treatment side evaluated the skin hydration, melanin content, erythema, and elasticity of both cheeks using a corneometer, a mexameter, and a reviscometer, respectively, at each follow-up visit (0, 1, 2, 4, 8, and 12 weeks postinjection). The subjects and two independent investigators assessed the clinical improvement using the Global Aesthetic Improvement Scale (GAIS) at the every visit. Twenty-four participants completed the study, and no participants withdrew due to adverse effects.

INTERVENTIONS Each participant submitted to a single treatment with a NASHA injection to one side of the lower cheek. The cheek side to which the treatment was applied was chosen randomly.

Detailed Description

Twenty-five patients were recruited to this single-center, evaluator-blinded, prospective, balanced (1:1), split-face randomized clinical trial. Twenty-four participants completed the study, and no participants withdrew due to adverse effects. Each participant submitted to a single treatment with a NASHA injection to one side of the lower cheek. One dermatologist who was blinded as to the treatment side evaluated the skin hydration, melanin content, erythema, and elasticity of both cheeks using a corneometer, a mexameter, and a reviscometer, respectively, at each follow-up visit (0, 1, 2, 4, 8, and 12 weeks postinjection). The subjects and two independent investigators assessed the clinical improvement using the Global Aesthetic Improvement Scale (GAIS) at the every visit. Adverse events were self-reported by the patients completing a questionnaire.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
25
Inclusion Criteria
  • Healthy people older than 25 years
Exclusion Criteria
  • known hypersensitivity to HA, an active skin disease, any autoimmune disorder, or significant renal, hepatic, or other medical diseases

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
treated side (Restylane vital)Restylane VitalWe injected staabilized hyaluronic acid (HA)-based gel of nonanimal origin on the left side of face. (We performed split face study)
Primary Outcome Measures
NameTimeMethod
Erythema Index12 weeks

We measured an erythema index by a mexameter device (Courage \& Khazaka, Cologne, Germany).

The range of erythema index is 0\~999 AU(Arbitrary Unit). The range of erythema index was 0 (as non-erythematous as possible) \~999 AU (most erythematous possible)

Elasticity12 weeks

We measured a elasticity by a reviscometer device (Courage \& Khazaka, Cologne, Germany).

The range of elasticity was 0 (most elastic possible as) \~400 AU(Arbitrary Unit) (inelastic as possible)

Global Aesthetic Improvement Scale (Investigator)12 weeks

The therapeutic outcome was assessed by investigator using the Global Aesthetic Improvement Scale (GAIS), which rates outcome on the following 5-point scale: 3, very much improved; 2, much improved; 1, improved; 0, no change; and -1, worse.

Global Aesthetic Improvement Scale (Subject)12 weeks

The therapeutic outcome was assessed by patient self-assessment using the Global Aesthetic Improvement Scale (GAIS), which rates outcome on the following 5-point scale: 3, very much improved; 2, much improved; 1, improved; 0, no change; and -1, worse

Hydration Level12 weeks

We measured a hydration level by a corneometer device (Courage \& Khazaka, Cologne, Germany).

The range of hydration level was 0 (as dry as possible) \~120 AU (Arbitrary Unit)(most moist possible)

Melanin Index12 weeks

We measured a melanin index by a mexameter device (Courage \& Khazaka, Cologne, Germany).

The range of melanin index was 0 (as bright as possible) \~999 AU (Arbitrary Unit) (most dark possible).

Secondary Outcome Measures
NameTimeMethod