Comparison of Retinal Oxygenation and Retinal Vessel Diameters in Healthy Subjects and Patients With Diabetic Retinopathy or Retinal Vein Occlusion Between DVA and Oxymap
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 20
- 试验地点
- 1
- 主要终点
- Difference of oxygen saturation of retinal vessels between DVA and Oxymap T1
研究概览
简要总结
To date two different instruments are commercially available to measure retinal oxygen saturation and retinal vessel diameters: Dynamic Vessel Analyzer (DVA) and Oxymap. Retinal oxygen saturation analysis is based on spectroscopic evaluation of retinal fundus images. Up to now no data comparing both instruments for the measurement of retinal oxygen saturation and vessel diameter are available in the literature.
Study objectives: To compare retinal oxygenation and retinal vessel diameters in healthy subjects and patients with diabetic retinopathy or retinal vein occlusion between 2 commercially available systems (DVA, Oxymap T1)
Study design: Open pilot study
Study population:
30 healthy volunteers, age 18-80 years 30 type 2 diabetic patients with mild or moderate non-proliferative diabetic retinopathy, age 18-80 years 30 patients with retinal vein occlusion, age 18-80 years
Topically administered medication:
Tropicamide (Mydriaticum "Agepha"®, Agepha, Vienna, Austria), dose: 1-2 drops per study day for dilation of the pupil Oxybuprocainhydrochloride combined with sodium fluorescein (Thilorbin®, Alcon Pharma GmbH, Freiburg, Germany), dose: 1 drop in one eye for measurements of intraocular pressure Nonylacidvanillylamide combined with Nicotinic-acid--ß-butoxyethylester (Finalgon®, Boehringer Ingelheim RCV GmbH & Co KG, Vienna, Austria): topical on the earlobe
Methods:
Dynamic vessel analyzer Oxymap T1 Blood pressure and pulse rate measurement Applanation tonometry Oxygen and carbon dioxide partial pressure measurement in arterialized blood from earlobe
Main outcome variables:
Difference of oxygen saturation of retinal vessels between DVA and Oxymap T1
The motive for this investigation is to compare data between 2 commercially available instruments for the measurement of retinal oxygen saturation and retinal vessel diameter in healthy subjects as well as in patients with ocular disease associated with altered retinal oxygenation. Comparative data from both systems are currently not available. Data from this study will allow the comparison of studies performed with different systems. All oxygen measurement procedures are non-invasive and painless. Hence, the risk/benefit ratio appears to be acceptable.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Other
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 80 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •healthy volunteers
- •normal ophthalmic findings, ametropia < 3 dpt
- •men and women aged between 18 and 80 years
排除标准
- •Any of the following will exclude a subject from the study:
- •participation in a clinical trial in the 3 weeks preceding the study
- •symptoms of a clinically relevant illness in the 3 weeks before the first study day
- •pregnancy
研究组 & 干预措施
Healthy subjects
healthy study subjects, age 18-80 years
干预措施: Dynamic Vessel Analyzer (Other)
Healthy subjects
healthy study subjects, age 18-80 years
干预措施: Oxymap T1 (Other)
结局指标
主要结局
Difference of oxygen saturation of retinal vessels between DVA and Oxymap T1
时间窗: participants will be followed for the duration of outpatient clinic visit, an expected average of 1 days
次要结局
- Difference of retinal vessel diameter between DVA and Oxymap T1(participants will be followed for the duration of outpatient clinic visit, an expected average of 1 days)
研究者
Stefan Sacu
Prof. Dr.
Medical University of Vienna