临床试验/NCT02521116
NCT02521116已完成不适用

Comparison of Retinal Oxygenation and Retinal Vessel Diameters in Healthy Subjects and Patients With Diabetic Retinopathy or Retinal Vein Occlusion Between DVA and Oxymap

Medical University of Vienna1 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2016年2月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
20
试验地点
1
主要终点
Difference of oxygen saturation of retinal vessels between DVA and Oxymap T1

研究概览

简要总结

To date two different instruments are commercially available to measure retinal oxygen saturation and retinal vessel diameters: Dynamic Vessel Analyzer (DVA) and Oxymap. Retinal oxygen saturation analysis is based on spectroscopic evaluation of retinal fundus images. Up to now no data comparing both instruments for the measurement of retinal oxygen saturation and vessel diameter are available in the literature.

Study objectives: To compare retinal oxygenation and retinal vessel diameters in healthy subjects and patients with diabetic retinopathy or retinal vein occlusion between 2 commercially available systems (DVA, Oxymap T1)

Study design: Open pilot study

Study population:

30 healthy volunteers, age 18-80 years 30 type 2 diabetic patients with mild or moderate non-proliferative diabetic retinopathy, age 18-80 years 30 patients with retinal vein occlusion, age 18-80 years

Topically administered medication:

Tropicamide (Mydriaticum "Agepha"®, Agepha, Vienna, Austria), dose: 1-2 drops per study day for dilation of the pupil Oxybuprocainhydrochloride combined with sodium fluorescein (Thilorbin®, Alcon Pharma GmbH, Freiburg, Germany), dose: 1 drop in one eye for measurements of intraocular pressure Nonylacidvanillylamide combined with Nicotinic-acid--ß-butoxyethylester (Finalgon®, Boehringer Ingelheim RCV GmbH & Co KG, Vienna, Austria): topical on the earlobe

Methods:

Dynamic vessel analyzer Oxymap T1 Blood pressure and pulse rate measurement Applanation tonometry Oxygen and carbon dioxide partial pressure measurement in arterialized blood from earlobe

Main outcome variables:

Difference of oxygen saturation of retinal vessels between DVA and Oxymap T1

The motive for this investigation is to compare data between 2 commercially available instruments for the measurement of retinal oxygen saturation and retinal vessel diameter in healthy subjects as well as in patients with ocular disease associated with altered retinal oxygenation. Comparative data from both systems are currently not available. Data from this study will allow the comparison of studies performed with different systems. All oxygen measurement procedures are non-invasive and painless. Hence, the risk/benefit ratio appears to be acceptable.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Other
盲法
None

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者
是

入选标准

  • •healthy volunteers
  • •normal ophthalmic findings, ametropia < 3 dpt
  • •men and women aged between 18 and 80 years

排除标准

  • •Any of the following will exclude a subject from the study:
  • •participation in a clinical trial in the 3 weeks preceding the study
  • •symptoms of a clinically relevant illness in the 3 weeks before the first study day
  • •pregnancy

研究组 & 干预措施

Healthy subjects

Other

healthy study subjects, age 18-80 years

干预措施: Dynamic Vessel Analyzer (Other)

Healthy subjects

Other

healthy study subjects, age 18-80 years

干预措施: Oxymap T1 (Other)

结局指标

主要结局

Difference of oxygen saturation of retinal vessels between DVA and Oxymap T1

时间窗: participants will be followed for the duration of outpatient clinic visit, an expected average of 1 days

次要结局

  • Difference of retinal vessel diameter between DVA and Oxymap T1(participants will be followed for the duration of outpatient clinic visit, an expected average of 1 days)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Stefan Sacu

Prof. Dr.

Medical University of Vienna