Caretaker Hemodynamic Parameters Validation
- Conditions
- Blood PressureHeart Rate VariabilityLeft Ventricular Ejection TimeCardiac Output
- Interventions
- Device: Non-invasive hemodynamic measurements
- Registration Number
- NCT04685733
- Lead Sponsor
- CareTaker Medical LLC
- Brief Summary
Comparison studies comparing hemodynamic parameters provided by the Caretaker against respective Gold Standard references.
- Detailed Description
Comparison studies comparing hemodynamic parameters provided by the Caretaker against respective Gold Standard references.
Specifically, continuous beat-by-beat blood pressure readings against arterial catheter readings, continuous beat-by-beat left ventricular ejection times (LVET) against matching LVETs obtained from central catheters, cardiac output (CO) and stroke volume (SV) measures against thermo-dilution and Fick measurements, and standard HRV parameters based on Caretaker-provided inter-beat intervals (IBI) against the same HRV parameters obtained from ECG-based IBIs.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 120
- 18 years of age, who are able and willing to participate and have given written assent
-
Unable to give written assent
- <18 years of age
- No or poor finger pulse, as determined through visual inspection for ischemic hands
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Arm && Interventions
Group Intervention Description Group 1 Non-invasive hemodynamic measurements Comparison of blood pressure, LVET and CO/SV measures with respective Gold Standards Group 3 Non-invasive hemodynamic measurements Comparison of blood pressure and CO/SV measures with respective Gold Standards Group 2 Non-invasive hemodynamic measurements Comparison of blood pressure and HRV measures with respective Gold Standards
- Primary Outcome Measures
Name Time Method Cardiac output performance comparison Paired measurements over approximately 1 hour time frame Comparison with thermo-dilution-based cardiac output, agreement within 1 l/min.
Heart rate variability measures comparison Paired beat-by-beat readings over maximum of 2.5 hours session length Comparison with 5 HRV ECG-derived measures, agreement within performance of VitalConnect predicate device
Blood pressure performance comparison Paired beat-by-beat readings over maximum of 2.5 hours session length Comparison with arterial catheter-derived blood pressure, guidelines call for meeting a bias of 5 mmHg and a standard deviation of 8 mmHg
Left ventricular ejection time comparison Paired measurements over approximately 1 hour time frame Comparison with LVET derived from central catheter signal traces, agreement within 20 msec.
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
Caretaker Medical
🇺🇸Charlottesville, Virginia, United States