MedPath

Comparison Between Myocardial Tomoscintigraphies Using a Semiconductor Camera or a Conventional Camera

Not Applicable
Completed
Conditions
Myocardial Infarction
Ischemia
Registration Number
NCT02861235
Lead Sponsor
Central Hospital, Nancy, France
Brief Summary

Myocardial perfusion tomoscintigraphy is a routine medicine procedure to check for the presence and severity of abnormalities of myocardial perfusion, as well as the extension of infarction residua. However, actual imagery devices (gamma cameras) have low resolution and detection sensitivity. A new semiconductor camera has 8 to 10 time higher detection sensitivity and could allow proportionally diminishing injected activities or recording times. Only one pilot study has been recently published on this type of camera, the D.SPECT camera.

This study will compare images recorded during 15 to 20 minutes by conventional cameras and 2 to 4 minutes by D.SPECT camera in patients doing tomoscintigraphy under usual conditions. The purpose is to demonstrate the equivalence of images recorded by two camera types for diagnostic information and the secondary purpose is to demonstrate the superiority of the D.SPECT camera in terms of image quality.

Detailed Description

This study will be conducted in Nuclear Medicine departments (Nancy Hospital, Bichat Hospital in Paris, Pasteur private hospital in Toulouse), with D.SPECT camera (Cyclopharma). The D.SPECT camera recording will be realized following the conventional camera recording and will not modify the routine programmed examination. Recording times of D.SPECT camera will be maximum 2 minutes for imaging with a strong activity of technetium-99m labeled dye and maximum 4 minutes for imaging with thallium-201 or with a low activity of technetium-99m labeled dye.6 study groups will be analyzed: 4 groups of patients initially doing stress tomoscintigraphy with thallium-201 (group 1) or with technetium-99m labeled dye and then testing 3 principal injection sequences (group 2, 3, 4), and 2 groups of patients initially doing "myocardial viability" assessment with rest tomoscintigraphy with thallium-201 (group 5) or technetium-99m labeled dye.

Recording comparison obtained with 2 cameras will be done according to qualitative and quantitative criteria on image quality and analyzing diagnosis concordance (presence, type and severity of observed abnormalities).

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
276
Inclusion Criteria
  • Understanding and signature of informed consent
  • Without any contraindication for tomoscintigraphy and stress techniques according to French Society of Cardiology and Nuclear Medicine criteria, as established for all patients doing this routine examination
  • Not in emergency situation and with a stable clinical status (without any sign of heart or coronary failure, without uncontrolled high blood pressure under treatment)
  • Having an effective contraception for women of childbearing potential
Exclusion Criteria
  • Patient under guardianship

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Primary Outcome Measures
NameTimeMethod
Telesystolic volume of link ventricleday 0
Diagnosis of stress ischemia with Myocardial Tomoscintigraphy dataday 0
Telediastolic volume of link ventricleday 0
Area of damaged regions of heartday 0
Ejection fraction of link ventricleday 0
Secondary Outcome Measures
NameTimeMethod
Qualitative score of image qualityday 0
Global myocardial activityday 0

Trial Locations

Locations (3)

Service de Médecine Nucléaire, Hôpital de Bichat, Assistance Publique des Hôpitaux de Paris

🇫🇷

Paris, France

Service de Médecine Nucléaire, Clinique Louis Pasteur

🇫🇷

Toulouse, France

Service de Médecine Nucléaire, Hôpital de Brabois, CHU de Nancy

🇫🇷

Vandoeuvre-les-Nancy, France

Service de Médecine Nucléaire, Hôpital de Bichat, Assistance Publique des Hôpitaux de Paris
🇫🇷Paris, France

MedPath

Empowering clinical research with data-driven insights and AI-powered tools.

© 2025 MedPath, Inc. All rights reserved.