MedPath

The Closed Kinetic Chain Lower Extremity Stability Test (CKCLEST): A New Clinical Performance Test

Not Applicable
Completed
Conditions
Healthy
Interventions
Procedure: Some clinical evaluation performance tests together with procedure of Closed Kinetic Chain Lower Extremity Stability Test
Registration Number
NCT04695574
Lead Sponsor
Gazi University
Brief Summary

It becomes important to evaluate closed kinetic chain activity. The aim of this study was to develop and to determine the test-retest, intra- and interreliability, and validity of the Closed Kinetic Chain Lower Extremity Stability Test (CKCLEST).

Detailed Description

Closed kinetic chain activities and exercises are used more and more in rehabilitation programs as they take place in daily life as functional movements. Therefore, it becomes important to evaluate closed kinetic chain activity. The aim of this study is to develop and to determine the test-retest, intra- and interreliability, and validity of the Closed Kinetic Chain Lower Extremity Stability Test (CKCLEST). Three-blinded, cross-sectional, repeated-measures clinical measurement reliability trial. To assess the reliability of CKCLEST, intraclass correlation coefficient (ICC), standard error of measurement (SEM), minimal detectable change (MDC), and Bland-Altman plot will be used. For concurrent validity of CKCLEST will be applied Spearman correlation analysis with Vertical Jump Test, Isokinetic Dynamometer Test, Single Leg Hop Test, and Prone Bridge Test. All analyses were made for both the best score and the average score. This test allows the evaluation of functional lower extremity stability, static/dynamic control of the lower extremity (knee/hip) or trunk, and simultaneous activation of the quadriceps and hamstring muscles / such coactivation.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
50
Inclusion Criteria
  • Individuals who healthy adults,
  • Volunteer
Exclusion Criteria
  • Surgery last six months and pain,
  • Disability,
  • Instability,
  • Limited range of motion in knee function,
  • Chronic diseases

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Volunteer young adultsSome clinical evaluation performance tests together with procedure of Closed Kinetic Chain Lower Extremity Stability TestHealthy young adults
Primary Outcome Measures
NameTimeMethod
To determine the concurrent validity of the Closed Kinetic Chain Lower Extremity Stability Test (CKCLEST)45 minutes

For concurrent validity of CKCLEST was applied Spearman correlation analysis with Vertical Jump Test, Isokinetic Dynamometer Test, Single Leg Hop Test, and Prone Bridge Test.

Secondary Outcome Measures
NameTimeMethod
To determine the the test-retest, intra- and interrater reliability of the Closed Kinetic Chain Lower Extremity Stability Test (CKCLEST)4 minutes, 7-14 days apart.

To assess the reliability of CKCLEST, it was applied twice.

Trial Locations

Locations (2)

Halime ARIKAN

🇹🇷

Ankara, Çankaya, Turkey

Gazi University

🇹🇷

Ankara, Turkey

© Copyright 2025. All Rights Reserved by MedPath