Comparison of Quantitative Metamorphopsia- Measurements in Patients With mCNV
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 23
- 试验地点
- 1
- 主要终点
- Metamorphopsia index change from baseline (no mCNV activity) to month 6 and 12 and all visits in between (disease activity dependent) for the following two devices - AMD-A Metamorphopsia Detector® (app4eyes - TEST) - Alleye® Test
研究概览
简要总结
The myopic CNV (mCNV) is a blood vessel neoplasm starting from the choroid, based on pathological myopia (severe myopia).
Choroidal neovascularization secondary to pathological myopia is the most common cause of severe visual impairment in myopic patients younger than 50 years old. Because untreated small fibrovascular membranes cause rapid damage to the photoreceptors, timely treatment is required in view of poor spontaneous prognosis1.
Metamorphopsia is the first functional impairment which occurs in mCNV - visual acuity loss and scotoma follow later.
There is a need for better and quicker quantifying of the metamorphopsia in mCNV patients.
The aim of this study is to detect metamorphopsia and verify correlations of different indexes with disease activity or not, measured in Optical Cohorence Tomography (OCT), best corrected visual acuity (BCVA), Vision related quality of life questionnaire (NEI-VFY-25) and quantify severity of metamophopsia.
详细描述
The myopic CNV is a neovascularization starting from the choroid and growing into the space between choroid and retina, based on pathological myopia (severe myopia). Choroidal neovascularization secondary to pathological myopia (mCNV) is the most common cause of severe visual impairment in myopic patients younger than 50 years old.1 As untreated subretinal fibrovascular membranes cause rapid damage to the photoreceptors, timely treatment is required in view of poor spontaneous prognosis.1
Metamorphopsia is the first functional impairment which occurs in mCNV - visual acuity loss and scotoma follow later. The Amsler Grid, a qualitative paper test developed the swiss ophthalmologist Marc Amsler (1891 - 1968), is a square-shaped grid used to detect or monitor metamorphopsia or scotoma involving the central visual field in various disorders of the macula and optic nerve head11.
Myopic CNV patients use the Amsler Grid as a home monitoring device for qualitative detection of metamorphopsia by checking the grid regularly11. Due to subretinal scarring in mCNV interpretation is often difficult and early changes cannot be detected and quantified. Until now there are no quantitative measurements for mCNV monitoring in clinical use.
Recently, two devices to detect and monitor metamorphopsia using smart phones and PCs, respectively, have been developed for use in choroidal neovascularization in age-related macular degeneration.5,6
- Alleye® Test Alleye® Test is a mobile medical software application indicated for the detection and characterization of metamorphopsia. For the mean Alleye score (±standard deviation (SD) deviations of dots from an ideal line are calculated for each eye.5
- AMD-A Metamorphopsia Detector® Is based on the Amsler grid. The software uses the concept of a negative image: a distorted image can be straightened by moving the mouse. Degree and dimension of distorted lines or scotoma are transformed into indices.6
研究设计
- 研究类型
- Observational
- 观察模型
- Other
- 时间视角
- Prospective
入排标准
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •diagnosis of mCNV involving the juxtafoveal or/and foveal region
- •BCVA >0.1 (20/200, Snellen)
- •ability to follow the study procedures
- •given written consent to participation
- •>18 years
排除标准
- •history of vitreoretinal surgery (including membrane peeling and retinal detachment surgery) to the study eye
- •presence of macula foramen or epiretinal membrane with significant distortion of retinal architecture
- •history of any side effects to Tropicamide eye drops
结局指标
主要结局
Metamorphopsia index change from baseline (no mCNV activity) to month 6 and 12 and all visits in between (disease activity dependent) for the following two devices - AMD-A Metamorphopsia Detector® (app4eyes - TEST) - Alleye® Test
时间窗: 1 year
Metamorphopsia index change (disease activity)
次要结局
- CRT (central retinal thickness) measured in OCT(1 year)
- -outer retina disruption score within central 1mm (measured in OCT) -maximum CNV thickness within central 1mm (measured in OCT) -area of pigment epithelium atrophy within central 1mm measured in autofluorescence imaging(1 year)
- NEI VFQ-25 questionnaire -BCVA (best corrected visual acuity)(1 year)
研究者
PD Dr. med. Katja Hatz
Head of clinical research and medical retina, Vista Klinik
Vista Klinik