DE-CT vs. SE-CT as Optimal Imaging During Treatment for Adaptive Proton Therapy in Stage III Non Small Cell Lung Cancer (NSCLC)

Maastricht Radiation Oncology2 个研究点 分布在 1 个国家开始时间: 2016年9月1日最近更新:
适应症

试验速览

阶段
不适用
状态
撤回
发起方
试验地点
2
主要终点
Dose distribution on the CTV (measured in Gy)

研究概览

简要总结

Dose distribution calculations for proton therapy are more accurate when based on DE-CT than on SE-CT. It is however unclear what the quantitative benefit of repeated DE-CT calculations is for lung cancer patients.

详细描述

In order to calculate the dose distribution of protons adequately, accurate estimations of the stopping power ratio (SPR) medium to water, are required. Using a conversion from single energy CT (SE-CT) images results in an uncertainty in the SPR of at least 3-4%. This uncertainty results in in the use of larger margins around the clinical target volume (CTV) and hence more dose to the organs at risk (OAR). It also effects in the conservative use of beam directions, which are often sub-optimal, to avoid irradiating normal tissues.

Dual energy CT (DE-CT) improves the accuracy of the SPR and therefore the proton range estimation.

An evaluation of the proton range for several tissues using SE-CT and DE-CT as input to Monte Carlo (MC) simulations showed on average improvements in range prediction from 0.1% to 2.1% when using DECT instead of SECT, but in several phantoms and also versus proton-CT, the errors on SE-CT based proton stopping power ratios are reported to be more than 7 %.

A limitation of these studies is that most of them were performed in phantoms. In the first clinical data set on five patients with base of skull tumours, it was reported that although the SPR estimation was indeed better for DE-CT than for SE-CT, its clinical relevance was unclear. However, in the same study, phantom measurements showed a large uncertainty of the SPR in the lung. This is due to the large heterogeneity of the lungs and the huge difference in the density of the lungs compared to the mediastinum, the tumour and the chest cavity.

It is therefore important to study the SPR differences of SE-CT compared to DE-CT in lung cancer patients and the impact on the dose distribution especially in the context of adaptive radiotherapy. As during the course of concurrent chemotherapy and radiotherapy, which is the standard treatment in the majority of stage III lung cancer patients, important anatomical changes may occur, it is also of clinical relevance to determine the influence of repeated dose calculations on DE-CT.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Other
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Histologically or cytologically confirmed locally advanced stage IIIA or III B (T0-4 N2-3M0) NSCLC, or M1 oligometastatic disease according to 7th TNM classification.
  • Scheduled to receive concurrent chemotherapy and radiotherapy to a dose of at least 60 Gy, as decided at the multidisciplinary tumour board
  • Able to give written informed consent
  • Able to have adequate contraception in woman with child bearing potential

排除标准

  • Not able to give written informed consent
  • Not able to comply with adequate contraception in woman with child bearing potential

结局指标

主要结局

Dose distribution on the CTV (measured in Gy)

时间窗: Measured during 2nd and 4th week of radiation treatment

Dose distribution on the CTV (clinical target volume) of the tumour and the lymph nodes of DE-CT vs. SE-CT

Dose distribution on the OAR (measured in Gy)

时间窗: Measured during 2nd and 4th week of radiation treatment

Dose distribution on the OAR (organs at risk), lungs, heart, aorta, pulmonary artery, superior vena cava, oesophagus, spinal cord, vertebral body, of DE-CT vs. SE-CT

次要结局

未报告次要终点

研究者

发起方
Maastricht Radiation Oncology