跳至主要内容
临床试验/NCT04081311
NCT04081311已完成不适用

A Comparison of the Efficacy of Interdental Floss to Water Flosser Around Dental Implants in Maintenance Patients: a Randomized Controlled Trial

University of Manitoba2 个研究点 分布在 1 个国家目标入组 33 人开始时间: 2019年9月6日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
33
试验地点
2
主要终点
Probing Depth (PD) around dental implants

研究概览

简要总结

The primary objective of this study was to compare two different interproximal devices, water flosser and dental floss around implants in several clinical parameters

详细描述

This study was a randomized, controlled clinical trial in a single center. All clinical measurements were taken by a single blinded investigator (Periodontal Resident) while a single dental hygienist was responsible for prophylaxis and delivery of oral hygiene instructions to the study participants. At each appointment 5 clinical parameters were recorded: Full Mouth Plaque Score (FMPS) and Quigley-Hein plaque index (QHI) of the implants after the use of a disclosing solution, Probing Depth (PD), Bleeding on Probing (BOP) of the study implants recorded at 6 sites (distobuccal, mid-buccal, mesiobuccal, distolingual, mid-lingual and mesiolingual) using a UNC 12 Colorvue probe and the width of the keratinized tissue (KT) at the buccal surface of the study implants. Randomization between the 2 groups was achieved using computerized randomization scheme (https://en.calc-site.com/randoms/grouping).

Group A (control): patients were instructed to floss with TePe Bridge and Implant Floss once a day, preferably at nighttime.

Group B (test): patients were provided with Waterpik Water Flosser and instructed to water floss around the implant once a day, preferably at nighttime.

During each appointment the study investigator measured clinical parameters and participants received oral hygiene instructions (OHI) and supportive periodontal therapy (SPT) by a single dental hygienist. Once the study was concluded patients were asked to fill-out a 2 question questionnaire inquiring how much they liked their interproximal device and how easy it was to be used in a scale 1 to 5.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Supportive Care
盲法
Single (Investigator)

盲法说明

All clinical measurements were taken by a single blinded investigator (Periodontal Resident) while a single dental hygienist was responsible for prophylaxis and delivery of oral hygiene instructions to the study participants

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients that present with at least a single implant with a screw-retained crown
  • Patients with general good health that do not have a condition contra-indicating routine dental treatment
  • Patients that are compliant with the research protocol and methods
  • Patients that have read, understood and signed the informed consent form

排除标准

  • Patients with implants with cemented crowns
  • Patients with any contact hypersensitivity to the related materials used in the study
  • Tobacco users (vaping included)
  • Patients unwilling to sign the informed consent form or follow the protocol of the study

结局指标

主要结局

Probing Depth (PD) around dental implants

时间窗: All participants have been seen at baseline, follow-up 1 (interval ranging between 3 to 6 months)

to evaluate the differences of a waterfloss system compared to flossing in Probing Depth (PD) around dental implants. PD is the measurement of the depth of a sulcus by measuring in millimeters the distance from a gingival margin to the base of the sulcus with a calibrated periodontal probe.

keratinized tissue (KT) around dental implants

时间窗: All participants have been seen at baseline, follow-up 1 (interval ranging between 3 to 6 months)

to evaluate the differences of a waterfloss system compared to flossing in the width of keratinized tissue (KT) around dental implants. KT is the stratified, squamous epithelium, that lines the vestibular and oral surfaces of the gingiva.

Change in BOP (bleeding on probing) index around dental implants

时间窗: All participants have been seen at baseline, follow-up 1 (interval ranging between 3 to 6 months)

to determine the effectiveness of a waterfloss system compared to flossing in changing the bleeding on probing (BOP) index around dental implants. BOP is a sign of inflammation and is recorded as yes/no (yes for bleeding, no for absence of bleeding). BOP is a percentage calculated by dividing the number of bleeding sites divided by the total number of sites of each implant. A lower percentage indicates lower inflammation

Full Mouth Plaque Score (FMPS)

时间窗: All participants have been seen at baseline, follow-up 1 (interval ranging between 3 to 6 months)

to determine the differences between water flosser compared to flossing in changing the Full Mouth Plaque Score (FMPS). FMPS is a percentage calculated by dividing the number of plaque containing surfaces divided by the total number of available surfaces of each tooth/implant. A lower percentage indicates lower total plaque and means better plaque control

Quigley-Hein plaque index (QHI) around dental implants

时间窗: All participants have been seen at baseline, follow-up 1 (interval ranging between 3 to 6 months)

to determine the differences of a waterfloss system compared to flossing in (QHI) around dental implants. Quigley-Hein plaque index (QHI) is a scale 0 to 5. 0 no plaque. 1. separate flecks of plaque at the cervical margin of the tooth. 2. a thin continuous band of plaque (up to one mm) at the cervical margin of the tooth. 3. a band of plaque wider than one mm but covering less than one-third of the crown of the tooth. 4. plaque covering at least one-third but less than two-thirds of the crown of the tooth. 5. plaque covering two-thirds or more of the crown of the tooth. A lower number indicates better plaque control.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验

A Comparison of the Efficacy of Interdental Floss to... | 临床试验