Lidocaine Versus Bupivacaine in Ambulatory Continuous Block With Elastomeric Pump
- Registration Number
- NCT02121119
- Lead Sponsor
- Pontificia Universidad Catolica de Chile
- Brief Summary
In practice ambulatory orthopedic surgery, one of the problems of most difficult solution is adequate control of postoperative analgesia. Pain is a frequent cause of consultation and unscheduled readmissions in this group of patients.
The use of continuous peripheral nerve blocks are an effective tool in postoperative analgesia.
In this connection, most of the studies of continuous infusions of local anesthetics by perineural catheters have been made with bupivacaine, levobupivacaine, and ropivacaine However, it has been found that lidocaine action lasts less, has lower cost and is less toxic than longer-acting agents.
The investigators aim is to compare the effectiveness of lidocaine versus bupivacaine continuous popliteal sciatic blockade ambulatory elastomeric pump.
- Detailed Description
In the practice of orthopedic outpatient surgery, one of the most intractable problems is proper control of post-operative analgesia . Pain is a frequent cause of consultations and unscheduled readmissions in this group of patients.
The use of continuous peripheral nerve blocks are an effective tool in postoperative analgesia , allowing prolong the effect of the blockade by the time you want. Such techniques have been described by different groups for the management of postoperative pain with good results even successfully used in ambulatory practice .
However, sending patients home with a continuous infusion pump to local anesthetics causes some problems , such as the method of administration , cost and risk of poisoning by these drugs.
With regard to the method of administration , have been used electronic continuous infusion pumps even allow boluses of demand , with good results. However, its use implies a higher cost and are more difficult to use by patients.
An alternative of greater simplicity and lower cost is the use of disposable pumps ( elastomeric pumps ) without electronic components , which through a simple mechanism to allow a predetermined continuous infusion flow . It has been seen that the use of elastomeric pumps for continuous peripheral nerve blocks are associated with fewer technical problems and more satisfied patients electronic pumps .
Another problem that occurs with the use of ambulatory continuous technical risk is secondary to the administration of local anesthetic solutions long-acting toxicity in a home environment , without immediate medical intervention. While this is a potential risk of toxicity , this problem could be avoided by using less toxic drugs .
In this connection , most of the studies of continuous infusion of local anesthetics by perineural catheters have been made with bupivacaine , levobupivacaine , and ropivacaine . However, it has been found that lidocaine lasts less action , has a lower cost and is less toxic than the long-acting agents , although no studies which continuous infusion of lidocaine home . In addition , there is evidence of comparable effectiveness between solutions of bupivacaine and lidocaine in continuous epidural infusion for postoperative analgesia , why lidocaine is likely to be a good alternative for continuous ambulatory blocks .
Therefore, the investigators objective is to compare the effectiveness of lidocaine versus bupivacaine in ambulatory popliteal sciatic blockade with continuous elastomeric pump .
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 70
- American Society of Anesthesiologists I or II
- Body mass index between 20 and 34 kg/m2
- Bilateral surgery of ankle or foot.
- Peripheral nerve block and general anesthesia
- Chronic pain.
- Illicit drug use
- Pregnancy
- Psychiatric disease
- Chronic use of analgesia
- Peripheral neuropathy
- History of severe Gastroesophageal reflux disease
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description Bupivacaine Bupivacaine Infusion of 0.1% bupivacaine hour to 5 ml Baxter Infusor elastomeric pump 5 ml / hr. Lidocaine Lidocaine 0.5% lidocaine infusion hour to 5 ml Baxter Infusor elastomeric pump 5 ml / hr.
- Primary Outcome Measures
Name Time Method Resting Visual Analogue Scale average in the first 24 hours 1 day Visual analogue scale
- Secondary Outcome Measures
Name Time Method Problems patient using the pump 7 days Survey of local anesthetic toxicity, patient falls, catheter and exits pump problems,
Worse daily Visual Analogue Scale 7 days Visual analogue scale
Patient satisfaction 7 days five point likert
Number of patients using rescue analgesia and number of doses per patient 7 days Milligrams of tramadol used
Resting and dynamic Visual Analogue Scale average in Post anesthesia care unit, 48, 72 hours and 7 days 7 days Visual analogue scale
Trial Locations
- Locations (1)
División de Anestesia - Facultad de Medicina Pontificia Universidad Católica
🇨🇱Santiago, Región Metropolitana, Chile