Comparaison Between Ultrasound-guided Distal and Proximal Approaches for Radial Artery Catheterization in Intensive Care Unit

University Tunis El Manar2 个研究点 分布在 1 个国家目标入组 94 人开始时间: 2021年3月26日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
94
试验地点
2
主要终点
The overall access time

研究概览

简要总结

Patients were randomly divided into two groups: ultrasound-guided (US-guided) in-plane distal radial access (IP-DRA) and in-plane proximal radial access (IP-PRA) catheterization.

For IP-DRA , a linear transducer is placed in the radial fossa, which is known as the snuff-box. After obtaining a long-axis view of the radial artery ,the needle is inserted in the midpoint of the small footprint transducer. Then,the needle is advanced under real-time US guidance until visualizing the tip of the needle inside the artery .

For IP-PRA , a linear transducer is placed in the standard conventional forearm radial.

After obtaining a long-axis view of the radial artery ,the needle is inserted in the midpoint of the small footprint transducer. Then,the needle is advanced under real-time US guidance until visualizing the tip of the needle inside the artery .

详细描述

*Ultrasound-guided catheterization of the radial artery, by proximal approach:

  • Patient's hand in hyperextension with slight dorsiflexion of the wrist.
  • The placement of the ultrasound probe initially linear in order to obtain the "short axis" image of the artery; then a quarter turn until obtaining a longitudinal "long axis" view.
  • The operator must identify the artery using the pulsed wave Doppler;
  • Insertion of the needle in the middle of the transducer providing an "in plane" orientation. Thus the needle was advanced slowly and its tip was visualized throughout the procedure. *Ultrasound-guided catheterization of the radial artery, by distal approach:
  • If the right hand is along the body / if the left hand is on the trunk.
  • The ultrasound probe placed at the level of the anatomical snuffbox by placing the transducer in a linear fashion then rotated coronally until a longitudinal image is obtained *In the 2 groups: - The longitudinal "in plane" approach is used - After visualization of the penetration of the bevel of the needle into the lumen of the artery and the jet of arterial blood into the syringe on aspiration, a flexible metal guide was introduced into the artery through the trocar according to the Seldinger's method. - The correct positioning of the guide in the artery was then confirmed by ultrasound. Any obstacle preventing insertion of the guide system always led to a new puncture.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Basic Science
盲法
Single (Participant)

入排标准

年龄范围
15 Years 至 90 Years(Child, Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients admitted in intensive care unit requiring a central venous catheter (CVC)

排除标准

  • Patients with radial AV shunt for hemodialysis
  • Patients with Renaud phenomenon or lymphedema
  • Congenital or acquired deformity of arms
  • Cannulation site infection, hematoma and surgery

结局指标

主要结局

The overall access time

时间窗: During the cannulation procedure

Time from the ultrasound scanning to the ultrasound confirmation of the correct position of the guidewire .

次要结局

  • 5. Rare complications(After 01 weeks of the procedure.)
  • 2. Puncture Attempts(During the procedure)
  • 3. The guidewire time(during the procedure)