coMparison Between invAsive and Non-invasive assessmenT on Blood Pressure and Cardiac Function in HealthY Participants

Conditions
Healthy Volunteer
Interventions
Diagnostic Test: Invasive left ventricular diastolic function assessment
Diagnostic Test: Invasive aortic blood pressure measurement
Diagnostic Test: Non-Invasive left ventricular diastolic function assessment
Diagnostic Test: Non-Invasive aortic blood pressure measurement
Registration Number
NCT03372616
Lead Sponsor
Shanghai 10th People's Hospital
Brief Summary

This is a cross-sectional cohort study which aims to compare the invasive and non-invasive assessments on aortic blood pressure and cardiac funtion in subjects without history of cardio-vascular disease. Left ventricular (LV) filling pressure, LV volume, and aortic blood pressure will be measured invasively. Non-invasive assessment includes echocardiography,aortic, and carotid blood pressure measurement.

Detailed Description

Not available

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
100
Inclusion Criteria
  • Over or equal to 18 years old;
  • Agree to participate the study and sign informed written consent;
  • Any change of drugs which effect the hemodynamics during 1 month prior to enrollment;
  • Proposed to perform coronary angiography and left left ventriculography in hospital;
Exclusion Criteria
  • Non-sinus rhythm or frequent extra systoles;
  • Identified coronary artery disease via coronary angiography;
  • Diagnosed pulmonary vascular or parenchymal disease;
  • Hypertrophic cardiomyopathy, restrictive cardiomyopathy, or constrictive pericarditis;
  • Stenosis or insufficiency of valves (moderate and above);
  • Heart transplant;
  • Congenital heart disease;
  • Inadequate imaging or doppler parameter quality in echocardiography.

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
All participantsInvasive left ventricular diastolic function assessmentAortic blood pressure, LV filling pressrue, and LV volume will be measured in all participants. Meanwhile, echocardiography and non-invasive aortic blood presure measurement will be performed. Three devices will be used in non-invasive aortic blood presure measurement, including Sphygmocor (AtCor Medical, Australia), PulsePen (DiaTecne SRL, Italy), and Mobil-O-Graph (IEM, Germany). In conclusion, all participants will receive invasive and non-invasive left ventricular diastolic function assessment, together with invasive and non-invasive aortic blood pressure assessment.
All participantsNon-Invasive left ventricular diastolic function assessmentAortic blood pressure, LV filling pressrue, and LV volume will be measured in all participants. Meanwhile, echocardiography and non-invasive aortic blood presure measurement will be performed. Three devices will be used in non-invasive aortic blood presure measurement, including Sphygmocor (AtCor Medical, Australia), PulsePen (DiaTecne SRL, Italy), and Mobil-O-Graph (IEM, Germany). In conclusion, all participants will receive invasive and non-invasive left ventricular diastolic function assessment, together with invasive and non-invasive aortic blood pressure assessment.
All participantsInvasive aortic blood pressure measurementAortic blood pressure, LV filling pressrue, and LV volume will be measured in all participants. Meanwhile, echocardiography and non-invasive aortic blood presure measurement will be performed. Three devices will be used in non-invasive aortic blood presure measurement, including Sphygmocor (AtCor Medical, Australia), PulsePen (DiaTecne SRL, Italy), and Mobil-O-Graph (IEM, Germany). In conclusion, all participants will receive invasive and non-invasive left ventricular diastolic function assessment, together with invasive and non-invasive aortic blood pressure assessment.
All participantsNon-Invasive aortic blood pressure measurementAortic blood pressure, LV filling pressrue, and LV volume will be measured in all participants. Meanwhile, echocardiography and non-invasive aortic blood presure measurement will be performed. Three devices will be used in non-invasive aortic blood presure measurement, including Sphygmocor (AtCor Medical, Australia), PulsePen (DiaTecne SRL, Italy), and Mobil-O-Graph (IEM, Germany). In conclusion, all participants will receive invasive and non-invasive left ventricular diastolic function assessment, together with invasive and non-invasive aortic blood pressure assessment.
Primary Outcome Measures
NameTimeMethod
Left ventricular filling pressure assessment with left heart catheterization1 day

All participants will receive invasive left ventricular filling pressure assessment with left heart catheterization.

Left ventricular diastolic function assessment with echocardiography using ASE recommendations1 day

All participants will receive non-invasive left ventricular diastolic function assessment with echocardiography. The ASE-recommended (American Society of Echocardiography) creteria would be used to define left ventricular diastolic dysfunction.

Left ventricular diastolic function assessment with echocardiography using EACVI recommendations1 day

All participants will receive non-invasive left ventricular diastolic function assessment with echocardiography. The EACVI-recommended (European Association of Cardiovascular Imaging) creteria would be used to define left ventricular diastolic dysfunction.

Secondary Outcome Measures
NameTimeMethod
Aortic blood presure obtained with Sphygmocor device1 day

Sphygmocor device (AtCor Medical, Australia) will be used in non-invasive aortic blood presure measurement with standard protocols shown in its user manual.

Aortic blood presure obtained with PulsePen device1 day

PulsePen device (DiaTecne SRL, Italy) will be used in non-invasive aortic blood presure measurement with standard protocols shown in its user manual.

Aortic blood presure obtained with Mobil-O-Graph device1 day

Mobil-O-Graph (IEM, Germany) device will be used in non-invasive aortic blood presure measurement with standard protocols shown in its user manual.

Aortic blood presure obtained with catheterization1 day

Catheterization will be used in invasive aortic blood presure measurement. The cather will be placed in the aortic root while measuring the blood pressure.