coMparison Between invAsive and Non-invasive assessmenT on Blood Pressure and Cardiac Function in HealthY Participants
- Conditions
- Healthy Volunteer
- Interventions
- Diagnostic Test: Invasive left ventricular diastolic function assessmentDiagnostic Test: Invasive aortic blood pressure measurementDiagnostic Test: Non-Invasive left ventricular diastolic function assessmentDiagnostic Test: Non-Invasive aortic blood pressure measurement
- Registration Number
- NCT03372616
- Lead Sponsor
- Shanghai 10th People's Hospital
- Brief Summary
This is a cross-sectional cohort study which aims to compare the invasive and non-invasive assessments on aortic blood pressure and cardiac funtion in subjects without history of cardio-vascular disease. Left ventricular (LV) filling pressure, LV volume, and aortic blood pressure will be measured invasively. Non-invasive assessment includes echocardiography,aortic, and carotid blood pressure measurement.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- UNKNOWN
- Sex
- All
- Target Recruitment
- 100
- Over or equal to 18 years old;
- Agree to participate the study and sign informed written consent;
- Any change of drugs which effect the hemodynamics during 1 month prior to enrollment;
- Proposed to perform coronary angiography and left left ventriculography in hospital;
- Non-sinus rhythm or frequent extra systoles;
- Identified coronary artery disease via coronary angiography;
- Diagnosed pulmonary vascular or parenchymal disease;
- Hypertrophic cardiomyopathy, restrictive cardiomyopathy, or constrictive pericarditis;
- Stenosis or insufficiency of valves (moderate and above);
- Heart transplant;
- Congenital heart disease;
- Inadequate imaging or doppler parameter quality in echocardiography.
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Arm && Interventions
Group Intervention Description All participants Invasive left ventricular diastolic function assessment Aortic blood pressure, LV filling pressrue, and LV volume will be measured in all participants. Meanwhile, echocardiography and non-invasive aortic blood presure measurement will be performed. Three devices will be used in non-invasive aortic blood presure measurement, including Sphygmocor (AtCor Medical, Australia), PulsePen (DiaTecne SRL, Italy), and Mobil-O-Graph (IEM, Germany). In conclusion, all participants will receive invasive and non-invasive left ventricular diastolic function assessment, together with invasive and non-invasive aortic blood pressure assessment. All participants Non-Invasive left ventricular diastolic function assessment Aortic blood pressure, LV filling pressrue, and LV volume will be measured in all participants. Meanwhile, echocardiography and non-invasive aortic blood presure measurement will be performed. Three devices will be used in non-invasive aortic blood presure measurement, including Sphygmocor (AtCor Medical, Australia), PulsePen (DiaTecne SRL, Italy), and Mobil-O-Graph (IEM, Germany). In conclusion, all participants will receive invasive and non-invasive left ventricular diastolic function assessment, together with invasive and non-invasive aortic blood pressure assessment. All participants Invasive aortic blood pressure measurement Aortic blood pressure, LV filling pressrue, and LV volume will be measured in all participants. Meanwhile, echocardiography and non-invasive aortic blood presure measurement will be performed. Three devices will be used in non-invasive aortic blood presure measurement, including Sphygmocor (AtCor Medical, Australia), PulsePen (DiaTecne SRL, Italy), and Mobil-O-Graph (IEM, Germany). In conclusion, all participants will receive invasive and non-invasive left ventricular diastolic function assessment, together with invasive and non-invasive aortic blood pressure assessment. All participants Non-Invasive aortic blood pressure measurement Aortic blood pressure, LV filling pressrue, and LV volume will be measured in all participants. Meanwhile, echocardiography and non-invasive aortic blood presure measurement will be performed. Three devices will be used in non-invasive aortic blood presure measurement, including Sphygmocor (AtCor Medical, Australia), PulsePen (DiaTecne SRL, Italy), and Mobil-O-Graph (IEM, Germany). In conclusion, all participants will receive invasive and non-invasive left ventricular diastolic function assessment, together with invasive and non-invasive aortic blood pressure assessment.
- Primary Outcome Measures
Name Time Method Left ventricular filling pressure assessment with left heart catheterization 1 day All participants will receive invasive left ventricular filling pressure assessment with left heart catheterization.
Left ventricular diastolic function assessment with echocardiography using ASE recommendations 1 day All participants will receive non-invasive left ventricular diastolic function assessment with echocardiography. The ASE-recommended (American Society of Echocardiography) creteria would be used to define left ventricular diastolic dysfunction.
Left ventricular diastolic function assessment with echocardiography using EACVI recommendations 1 day All participants will receive non-invasive left ventricular diastolic function assessment with echocardiography. The EACVI-recommended (European Association of Cardiovascular Imaging) creteria would be used to define left ventricular diastolic dysfunction.
- Secondary Outcome Measures
Name Time Method Aortic blood presure obtained with Sphygmocor device 1 day Sphygmocor device (AtCor Medical, Australia) will be used in non-invasive aortic blood presure measurement with standard protocols shown in its user manual.
Aortic blood presure obtained with PulsePen device 1 day PulsePen device (DiaTecne SRL, Italy) will be used in non-invasive aortic blood presure measurement with standard protocols shown in its user manual.
Aortic blood presure obtained with Mobil-O-Graph device 1 day Mobil-O-Graph (IEM, Germany) device will be used in non-invasive aortic blood presure measurement with standard protocols shown in its user manual.
Aortic blood presure obtained with catheterization 1 day Catheterization will be used in invasive aortic blood presure measurement. The cather will be placed in the aortic root while measuring the blood pressure.