Accuracy of CVC Depth Prediction in Internal Jugular Veins: The Difference Between The Andropoulos and ECG Methods
- Conditions
- Depth of CVC Insertion
- Interventions
- Device: ECGOther: andropulous method
- Registration Number
- NCT04215250
- Lead Sponsor
- Indonesia University
- Brief Summary
compare the accuracy of CVC depth prediction in internal jugular veins: the difference between the andropoulos and ECG methods
- Detailed Description
seventy two subjects were given informed consent before the study started. compare the accuracy of CVC depth prediction in internal jugular veins with two difference methods, the andropoulos method and ECG method.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 72
- signing informed consent form
- indicated for CVC insertion
- has no contraindication for right internal jugular vein CVC insertion
- has history of arrhythmia
- has cardiac malformation history
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description ECG method ECG change in p wave from ECG Andropulous method andropulous method Andropulous method uses equations to determine the depth of CVC insertion. For subject with \<100 cm in height: Depth of CVC insertion (cm) = (height (cm)/ 10)-1 For subject with \>100 cm in height: Depth of CVC insertion (cm) = (height (cm)/ 10)-2
- Primary Outcome Measures
Name Time Method CVC prediction depth using andropulous equation 30 minutes CVC will be inserted in certain depth according to the calculated depth
- Secondary Outcome Measures
Name Time Method ECG change 30 seconds changes in p wave during CVC insertion
Trial Locations
- Locations (1)
Cipto Mangunkusumo Cental National Hospital
🇮🇩Jakarta, DKI Jakarta, Indonesia