MedPath

Accuracy of CVC Depth Prediction in Internal Jugular Veins: The Difference Between The Andropoulos and ECG Methods

Not Applicable
Completed
Conditions
Depth of CVC Insertion
Interventions
Device: ECG
Other: andropulous method
Registration Number
NCT04215250
Lead Sponsor
Indonesia University
Brief Summary

compare the accuracy of CVC depth prediction in internal jugular veins: the difference between the andropoulos and ECG methods

Detailed Description

seventy two subjects were given informed consent before the study started. compare the accuracy of CVC depth prediction in internal jugular veins with two difference methods, the andropoulos method and ECG method.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
72
Inclusion Criteria
  • signing informed consent form
  • indicated for CVC insertion
  • has no contraindication for right internal jugular vein CVC insertion
Exclusion Criteria
  • has history of arrhythmia
  • has cardiac malformation history

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
ECG methodECGchange in p wave from ECG
Andropulous methodandropulous methodAndropulous method uses equations to determine the depth of CVC insertion. For subject with \<100 cm in height: Depth of CVC insertion (cm) = (height (cm)/ 10)-1 For subject with \>100 cm in height: Depth of CVC insertion (cm) = (height (cm)/ 10)-2
Primary Outcome Measures
NameTimeMethod
CVC prediction depth using andropulous equation30 minutes

CVC will be inserted in certain depth according to the calculated depth

Secondary Outcome Measures
NameTimeMethod
ECG change30 seconds

changes in p wave during CVC insertion

Trial Locations

Locations (1)

Cipto Mangunkusumo Cental National Hospital

🇮🇩

Jakarta, DKI Jakarta, Indonesia