Clinical Performance of Toric Hydrogel Contact Lenses Following One Week of Daily Wear
- Conditions
- Astigmatism
- Interventions
- Device: filcon IV1 toric lensDevice: ocufilcon D toric lens
- Registration Number
- NCT02847169
- Lead Sponsor
- Coopervision, Inc.
- Brief Summary
The aim of this prospective study is to evaluate the clinical performance of filcon IV1 toric and ocufilcon D toric contact lenses after 1 week of wear in each pair.
- Detailed Description
This is a 30-subject, prospective, randomized, double masked, bilateral, 1 week cross-over study comparing the fitting characteristics of filcon IV1 toric lenses against ocufilcon D hydrogel toric lenses.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 30
-
A person is eligible for inclusion in the study if he/she:
- Is between 18 and 40 years of age (inclusive)
- Has had a self-reported visual exam in the last two years
- Is an adapted soft toric contact lens wearer
- Has a contact lens spherical prescription between +6.00 to - 9.00 (inclusive)
- Have no less than -0.75D of astigmatism and no more than -2.00 D in both eyes.
- Can achieve best corrected spectacle distance visual acuity of 20/25 (0.10 logMAR) or better in each eye.
- Can achieve a distance visual acuity of 20/30 (0.18 logMAR) or better in each eye with the study contact lenses.
- Has clear corneas and no active ocular disease
- Has read, understood and signed the information consent letter.
- Patient contact lens refraction should fit within the available parameters of the study lenses.
- Is willing to comply with the wear schedule (at least 5 days per week, > 8 hours/day assuming there are no contraindications for doing so).
- Is willing to comply with the visit schedule
-
A person will be excluded from the study if he/she:
-
Has a CL prescription outside the range of the available parameters of the study lenses.
-
Has a spectacle cylinder less than -0.75D or more than -2.00 D of cylinder in either eye.
-
Has a history of not achieving comfortable CL wear (5 days per week; > 8 hours/day)
-
Has contact lens best corrected distance vision worse than 20/25 (0.10 logMAR) in either eye.
-
Presence of clinically significant (grade 2-4) anterior segment abnormalities
-
Presence of ocular or systemic disease or need of medications which might interfere with contact lens wear. Confidential EX-MKTG-66 Clinical Performance of Toric Hydrogel Contact Lenses Following One Week of Daily Wear 10
-
Slit lamp findings that would contraindicate contact lens wear such as:
- Pathological dry eye or associated findings
- Pterygium, pinguecula, or corneal scars within the visual axis
- Neovascularization > 0.75 mm in from of the limbus
- Giant papillary conjunctivitis (GCP) worse than grade 1
- Anterior uveitis or iritis (past or present)
- Seborrheic eczema, Seborrheic conjunctivitis
- History of corneal ulcers or fungal infections
- Poor personal hygiene
-
Has a known history of corneal hypoesthesia (reduced corneal sensitivity)
-
Has aphakia, keratoconus or a highly irregular cornea.
-
Has Presbyopia or has dependence on spectacles for near work over the contact lenses.
-
Has undergone corneal refractive surgery.
-
Is participating in any other type of eye related clinical or research study.
-
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- CROSSOVER
- Arm && Interventions
Group Intervention Description filcon IV1 toric lens filcon IV1 toric lens Participants are randomized to wear filcon IV1 toric lens pair for 1 week during the cross over study. ocufilcon D toric lens ocufilcon D toric lens Participants are randomized to wear ocufilcon D toric lens pair for 1 week during the cross over study.
- Primary Outcome Measures
Name Time Method Overall Fit Acceptance Baseline and 1 week Investigator's preference for lens fit acceptance for habitual lenses assessed at baseline and filcon IV1 and ocufilcon D toric lenses assessed at baseline and 1 week. Scale 0-4, 0=should not be worn, 1=borderline but unacceptable, 2= minimally acceptable, early review, 3=not perfect but OK to dispense, 4=perfect
Post-blink Movement Baseline and 1 week Post-blink movement for habitual lenses assessed at baseline and filcon IV1 and ocufilcon D toric lenses assessed at baseline and 1 week. Scale 0-4, 0=insufficient, 1=minimal, but acceptable movement, 2=optimal movement, 3=moderate, but acceptable movement, 4=excessive, unacceptable movement.
Lens Centration Baseline and 1 week Lens centration for habitual lenses assessed at baseline and filcon IV1 and ocufilcon D toric lenses assessed at baseline and 1 week. (Centered - optimal, decentered slightly, or substantially decentered).
Overall Stability Baseline and 1 week Overall lens stability for habitual lenses assessed at baseline and filcon IV1 and ocufilcon D toric lenses assessed at baseline and 1 week. Scale 0-4, 0=very poor stability, 4=excellent stability.
Corneal Coverage Baseline and 1 week Corneal coverage for habitual lenses assessed at baseline and filcon IV1 and ocufilcon D toric lenses assessed at baseline and 1 week. (yes=full corneal coverage or no=not full coverage)
Lens Orientation in Primary Position of Gaze Baseline and 1 week Lens rotation for habitual toric lens assessed at baseline and filcon IV1 and ocufilcon D toric lenses assessed at baseline and 1 week with slit lamp by measuring within 10 degrees of the axis mark on the lens relative to the desired 6' o'clock position while the subject looked straight ahead.
Rotational Recovery in Degrees After 60 Seconds Baseline and 1 week Rotational recovery measured in degrees after 60 seconds for habitual toric lens assessed at baseline and filcon IV1 and ocufilcon D toric lenses assessed at baseline and at 1 week by slit lamp.
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
Optometry Clinic, National Autonomous University
🇲🇽Mexico D.F., Mexico