Skip to main content
Clinical Trials/NCT00372138
NCT00372138
Terminated
Not Applicable

Prevention of Endoleaks Using Autologous Platelet Gel During Endovascular Procedures on Unruptured Abdominal Aortic Aneurysms: Pilot Study

Rennes University Hospital1 site in 1 country20 target enrollmentSeptember 2006

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Abdominal Aortic Aneurysms
Sponsor
Rennes University Hospital
Enrollment
20
Locations
1
Primary Endpoint
Safety of the perioperative procedure for injecting PRP + autologous thrombin assessed by distal embolism, colic necrosis, aneurysm rupture.
Status
Terminated
Last Updated
14 years ago

Overview

Brief Summary

The main risk of aortic aneurysms is rupture that leads to a high risk of death. A preventive surgical treatment is thus needed. In order to reduce the morbidity and mortality associated with conventional surgery, an endovascular approach (insertion of an endovascular stent graft)is now widely favored. The main problem of this procedure is the occurrence of endoleaks (persistence of a communication between the aneurysm and the aorta). A new approach is proposed to prevent these endoleaks. The principle is to draw blood from the patient, separate the blood from the platelets, and reinject both platelet rich plasma (PRP) and autologous thrombin, in order to form a platelet gel (PRP + autologous thrombin). Before studying the efficacy of this technique, its safety of use and feasibility must be evaluated.

Detailed Description

The main risk of aortic aneurysms is rupture. Onset is usually sudden, leading to the death of the patient in 80% to 90% of cases. The elective treatment of abdominal aortic aneurysms, therefore, seems to be a priority. In order to reduce the morbidity and mortality associated with conventional surgery, an endovascular approach (insertion of an endovascular stent graft using the endovascular aneurysm repair procedure) is now widely favored. The main problem, during follow-up of patients wearing an endovascular stent graft, is the occurrence of endoleaks resulting in retrograde filling of the aneurysm sac. The ideal is to prevent these endoleaks either by new developments in endovascular stent grafts or by using adjuvant therapy during the procedure. The principle is to draw blood from the patient, separate the blood from the platelets, and reinject it into two separate catheters, one with platelet rich plasma (PRP) and the other with autologous thrombin, in order to form a platelet gel (PRP + autologous thrombin). Before studying the efficacy of this technique, its safety of use and feasibility must be evaluated.

Registry
clinicaltrials.gov
Start Date
September 2006
End Date
July 2008
Last Updated
14 years ago
Study Type
Interventional
Study Design
Single Group
Sex
All

Investigators

Sponsor
Rennes University Hospital
Responsible Party
Sponsor

Eligibility Criteria

Inclusion Criteria

  • Patient eligible to endovascular treatment:
  • Any patient having an infrarenal or aortoiliac abdominal aortic aneurysm needing surgical treatment,
  • With an infrarenal neck larger than 10 mm,
  • No thrombi in the neck,
  • Calcifications of the neck smaller than 30% of the circumference.
  • The maximum diameter of the aneurysm must be at least 50 mm and/or an annual growth rate of more than 10 mm and/or if the aneurysm is symptomatic,
  • With no major tortuosity of the two iliac axes with an aortoiliac angle greater than 80°,
  • An external iliac diameter of at least 8 mm,
  • An angle between the interrenal aorta and the neck of 0-45°.
  • The patient must meet at least one of the operability criteria of the French Health Products Safety Agency (AFSSAPS)

Exclusion Criteria

  • Patient with a hemostatic disorder, previously known or discovered during the preoperative lab work-up,
  • Patient whose arterial anatomy is incompatible with the criteria form use of a TALENT type endovascular stent graft,
  • Patient with an aneurysm whose rapid progression (risk of rupture) does not allow a radiological and scanographic assessments to be performed,
  • Patient allergic to the iodized contrast media,
  • Disease of the connective tissue (Marfan's Syndrome) or inflammatory aneurysm,
  • Patient with an aneurysm that includes the orifice of both internal iliacs,
  • Patient in whom it is essential to keep the inferior mesenteric artery permeable,
  • Patient surgically converted after failure of an endovascular technique,
  • Pregnant women,
  • Failure of stent graft insertion

Outcomes

Primary Outcomes

Safety of the perioperative procedure for injecting PRP + autologous thrombin assessed by distal embolism, colic necrosis, aneurysm rupture.

Time Frame: perioperative

* systemic hemodynamics (systolic, diastolic, and mean arterial pressure, before and after insertion of the endovascular stent graft, after insertion of the 2 injection catheters, and 1, 5, and 15 minutes after injection of the thrombin and PRP), * pressure inside the aneurysm 5 minutes after injection with the thrombin and PRP, * endoleaks at end of surgery, * distal embolism, colic necrosis, * rupture of the aneurysm, * prosthetic migration * plication, stenosis of the stent graft * thrombosis of the stent graft, * occlusive arterial lesion

Secondary Outcomes

  • Time to onset of endoleaks,(1 month)
  • Rate of complications related to the endovascular procedure.(1 month)
  • - Rate of early postoperative complications (< 30 days)(< 30 days)
  • Rate of occurrence of endoleaks at 1 month and types of endoleaks,(1 month)
  • Description of the perioperative surgical technique for injecting PRP + autologous thrombin(perioperative)

Study Sites (1)

Loading locations...