Skip to main content
Clinical Trials/NCT00628875
NCT00628875CompletedNot Applicable

"Feasibility of Ventilation Detection Using Thoracic Impedence Acquired Via Standard Defibrillator Electrode Pads in Mechanically Ventilated Pediatric Patients"

Children's Hospital of Philadelphia1 site in 1 country28 target enrollmentStarted: January 2007Last updated:
Conditions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Enrollment
28
Locations
1
Primary Endpoint
This is a pilot study to gather preliminary data. The primary endpoint is the accuracy of defibrillator pad detection of breaths >2ml/kg, compared to the gold standard pneumotachometer detection of breaths.

Study Overview

Brief Summary

This study is a prospective, observational case series of a convenience sample of mechanically ventilated pediatric patients in the Pediatric ICU, Progressive Care Unit and Operating Room at the Children's Hospital of Philadelphia.

We propose to observe, measure and report the accuracy, precision and bias of defibrillator electrode pads to detect breathing in stable but critically ill and mechanically ventilated children. This study will provide preliminary data to inform the resuscitation research community and assist development of evidence-based pediatric resuscitation guidelines in the future.

Detailed Description

Context: Resuscitation (CPR) guidelines recommend target values for rate and depth of rescue breathing and chest compressions. Defibrillator electrode pads can accurately detect the size, rate, and speed of machine-generated breaths in adults. The accuracy, precision, bias, and ability of the defibrillator electrode pads to detect the size, rate and speed of breathing in children have not been studied.

Objectives: The primary objective is to evaluate the accuracy, precision, bias and ability of the pads and defibrillator to detect the rate and depth of breathing in critically ill children on breathing machines. Important secondary objectives include reporting the accuracy, precision and bias of the measurement of the speed of the breath, measurement variability, and impact of alternative defibrillator electrode pad location on the chest.

Study Design/Setting/Participants:

Prospective, pilot, observational study in the Pediatric Intensive Care Unit and Progressive Care Unit at the Children's Hospital of Philadelphia. The participants are all patients in the PICU and Progressive Care Unit (PCU), 6 months to 17 years, who are supported by their clinical management team with a tracheal tube, standard breathing machine, and standard ICU monitoring systems.

Intervention:

Study Design

Study Type
Observational
Observational Model
Case Only
Time Perspective
Prospective

Eligibility Criteria

Ages
6 Months to 17 Years (Child)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • Patients age 6 months - 17 years with:
  • Artificial airway
  • Mechanical ventilation (PCV or VCV)
  • Hemodynamic stability to participate in the study, as determined by the clinical treatment team.
  • Parental/guardian permission (informed consent) and if appropriate, child assent.

Exclusion Criteria

  • Patients with chest tubes
  • High frequency ventilation (Jet or Oscillation)
  • Airway Pressure Release ventilation
  • Extracorporeal membrane oxygenation (ECMO)
  • Significant chest wall abnormality (e.g. Vertebral Expandable Prosthetic Titanium Rib (VEPTR) or device precluding typical placement of defibrillator electrode pads)
  • Altered skin integrity in areas where defibrillator electrode pads would be placed

Outcomes

Primary Outcomes

This is a pilot study to gather preliminary data. The primary endpoint is the accuracy of defibrillator pad detection of breaths >2ml/kg, compared to the gold standard pneumotachometer detection of breaths.

Time Frame: 1 year

Secondary Outcomes

No secondary outcomes reported

Investigators

Sponsor Class
Other

Study Sites (1)

Loading locations...

Similar Trials

Feasibility of Ventilation Detection Via... | Clinical Trial