跳至主要内容
临床试验/NCT02298049
NCT02298049已完成不适用

Satiation Attenuates BOLD Activity in Brain Regions Involved in Reward and Increases Activity in an Inhibitory Control Area: an fMRI Study in Healthy Volunteers.

University of Birmingham1 个研究点 分布在 1 个国家目标入组 16 人开始时间: 2010年7月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
16
试验地点
1
主要终点
Activation differences between satiated and pre-meal scan fMRI BOLD signal

研究概览

简要总结

To our knowledge no study has assessed the effects of a meal on neural responses to food cues and compared this with a condition simulating natural inter-meal hunger levels. This is important, as the existing literature often compares the effect of fasting to satiation, which may not reflect typical appetite processes. Thus, the purpose of this research was to examine the effect of a satiating lunch compared to a normal pre-meal state on blood oxygen level dependent (BOLD) activity in the human brain, as measured using functional magnetic resonance imaging (fMRI).

详细描述

We hypothesized that satiation would be associated with decreased brain activity across brain regions involved in both appetite and reward such as ventromedial prefrontal cortex, orbitofrontal cortex, ventral striatum, hypothalamus, insula, amygdala and hippocampus. 16 healthy participants (8 males) were scanned on two separate test days, before and after eating a meal to satiation, or after not eating for 4 hours (satiated vs. pre-meal). fMRI BOLD signals to the sight and/or taste of the stimuli were recorded. Participants were given questionnaires to complete about their mood state and appetite before and after all scans.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Basic Science
盲法
None

入排标准

年龄范围
18 Years 至 65 Years(Adult, Older Adult)
性别
All
接受健康志愿者
是

入选标准

  • •Healthy volunteers
  • •Sufficiently fluent in English to understand the task and the instructions

排除标准

  • •Currently taking medication
  • •Past or current depression/dieting,
  • •Food allergies
  • •Pregnancy
  • •BMI score outside the normal range
  • •Any contraindications to fMRI scanning (e.g. pacemakers, mechanical heart valve, hip replacement, metal implants)

研究组 & 干预措施

Scanning

Other

Repeated measures:

Satiation scan + Pre-meal scan

All participants undertook both scans

干预措施: Satiated / Pre-meal (Other)

Scanning

Other

Repeated measures:

Satiation scan + Pre-meal scan

All participants undertook both scans

干预措施: MRI (Device)

结局指标

主要结局

Activation differences between satiated and pre-meal scan fMRI BOLD signal

时间窗: 6 months

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验